9. Repeat steps 7 and 8 for every cue you want to add. Once all the cues
are added, save the XML file.
10.
Edit the
Dalapathi.exe.config
file found in the same folder and
change the ASCIIProtocolSerial baudrate value from
“COM1,115200,n,8,1” to “COM1,9600,n,8,1”:
•
Original line:
<add key="ASCIIProtocolSerial" value="COM1,115200,n,8,1"/> <!--Portname,baudrate,parity,databits,stopbits-->
•
Modified line:
<add key="ASCIIProtocolSerial" value="COM1,9600,n,8,1"/> <!--Portname,baudrate,parity,databits,stopbits-->
11.
After saving the modified files, logout from Windows session and
login again. Check on “logs” menu “qube” tab on Qube GUI the
PAASERIES device should have been added successfully.
12.
After performing these steps, automation cues can be selected
on the Qube GUI.
QUBE AUTOMATION FILES EXAMPLES
you can see an
example of the xml automation files extracted from a Qube XP-D server.
INSTALLATION MANUAL: PAA20+ V 2.0 (10/2021)
101
Summary of Contents for PAA20+
Page 1: ...INSTALLATION MANUAL PAA20 V 2 0 ...
Page 40: ...Figure 7 2 7D INSTALLATION MANUAL PAA20 V 2 0 10 2021 40 Figure 7 2 7E Figure 7 2 7F ...
Page 110: ...9 2 OUTPUT 2 CONNECTOR Figure 9 2A Picture 9 2B INSTALLATION MANUAL PAA20 V 2 0 10 2021 110 ...
Page 111: ...9 3 OUTPUT 3 CONNECTOR Figure 9 3A Figure 9 3B INSTALLATION MANUAL PAA20 V 2 0 10 2021 111 ...
Page 112: ...9 4 INPUT CONNECTOR Figure 9 4A Picture 9 4B INSTALLATION MANUAL PAA20 V 2 0 10 2021 112 ...
Page 114: ...9 5 2 INPUT WITH A POSITIVE COMMON Picture 9 5 2A INSTALLATION MANUAL PAA20 V 2 0 10 2021 114 ...