4. Backup the following files:
•
AutomationCues.xml
•
AutomationDevices.xml
5. Download the PAASERIES.xml
available in the FTP:
ftp://manual:[email protected]/manual/paa20+
, and
copy it in the XP folder.
6. Edit the
AutomationDevices.xml
, this file contains the definitions
and settings for all the devices the Qube server can handle. To add the
PAA20+ insert this text as a device tag:
<Device name="PAASERIES" class="Qube.Automation.StreamDevice.Serial" enable="true">
<Configuration>
<Key name="File" value="PAASERIES.xml" />
<Key name="Settings" value="COM1,9600,n,8,1" />
</Configuration>
</Device>
7. Edit the
AutomationCues.xml
, this file contains the definitions of the
output automation cues used by the Qube Software to control external
devices and internal actions. Adding new cues for the PAA20+ could be
done inserting new cue tags suche as the next example:
<Cue name="NameOfTheCue">
<Actions>
<InvokeMethod name="Name" device="PAASERIES"/>
</Actions>
</Cue>
8. On the previous example xml code, you have to change the
“NameOfTheCue”
field for the character string that will be shown on
the Qube Graphical User Interface (GUI) as the name of the
automation cue. You have to change the
“Name”
attribute on the
third line for the name associated to the output number and type
according to the table in
.
INSTALLATION MANUAL: PAA20+ V 2.0 (10/2021)
100
Summary of Contents for PAA20+
Page 1: ...INSTALLATION MANUAL PAA20 V 2 0 ...
Page 40: ...Figure 7 2 7D INSTALLATION MANUAL PAA20 V 2 0 10 2021 40 Figure 7 2 7E Figure 7 2 7F ...
Page 110: ...9 2 OUTPUT 2 CONNECTOR Figure 9 2A Picture 9 2B INSTALLATION MANUAL PAA20 V 2 0 10 2021 110 ...
Page 111: ...9 3 OUTPUT 3 CONNECTOR Figure 9 3A Figure 9 3B INSTALLATION MANUAL PAA20 V 2 0 10 2021 111 ...
Page 112: ...9 4 INPUT CONNECTOR Figure 9 4A Picture 9 4B INSTALLATION MANUAL PAA20 V 2 0 10 2021 112 ...
Page 114: ...9 5 2 INPUT WITH A POSITIVE COMMON Picture 9 5 2A INSTALLATION MANUAL PAA20 V 2 0 10 2021 114 ...