Chapter 8: Troubleshooting
269
Critical & Offline Disk Arrays
A fault-tolerant disk array—RAID 1, 1E, 5, 10, and 50—goes
critical
when a disk
drive is removed or fails. A RAID 6 disk array—goes
degraded
when a disk drive
is removed or fails and
critical
when two disk drives are removed of fail.
Due to the fault tolerance of the disk array, the data is still available and online.
However, once the disk array goes critical, the disk array has lost its fault
tolerance, and performance may be adversely affected.
If the fault was caused by a failed drive that was removed, the drive must be
replaced by another drive, either identical or larger, in order for the RAID system
to rebuild and restore optimal configuration.
If your fault-tolerant disk array—RAID 1, 1E, 5, 6, 10, and 50— goes
offline
,
contact Promise Technical Support. See “Contacting Technical Support” on
page 285.
A non-fault tolerant disk array—RAID 0—goes
offline
when a disk drive is
removed or fails. Since the disk array is not fault tolerant, the data stored in the
disk array is no longer accessible.
If one disk drive fails, all of the data on the disk array is lost. You must replace the
failed drive. Then, if the disk array had more than one disk drive, delete the disk
array and re-create it. Restore the data from a backup source.
When a Physical Drive Fails
VTrak provides both audible and visual indicators to alert you of a disk drive
failure. The following will occur when a disk drive fails or goes offline:
•
The Logical Drive LED changes from green to amber. See page 245.
•
The Disk Carrier Status LED changes from green to red. See page 246.
•
The audible alarm repeatedly sounds two short beeps. See page 244.
•
WebPAM PROe reports the condition. See page 252.
Also see “Physical Drive Problems” on page 273.
With a Hot Spare Drive
When a physical drive in a disk array fails and a spare drive of adequate capacity
is available, the disk array will begin to rebuild automatically using the spare
drive.
Warning
Take no further corrective action until you have consulted with
Promise Technical Support.
Summary of Contents for VTRAK M210i
Page 1: ...VTRAK M610i M310i M210i Product Manual Version 0 9 ...
Page 14: ...VTrak M610i M310i M210i Product Manual xiv ...
Page 22: ...VTrak M610i M310i M210i Product Manual 8 ...
Page 53: ...Chapter 4 Management with WebPAM PROe 39 Figure 1 The WebPAM PROe log in screen ...
Page 144: ...VTrak M610i M310i M210i Product Manual 130 ...
Page 212: ...VTrak M610i M310i M210i Product Manual 198 ...
Page 232: ...VTrak M610i M310i M210i Product Manual 218 ...
Page 256: ...VTrak M610i M310i M210i Product Manual 242 ...