7.4 Fitting the UV lamp protection tube
7.4.1 Fitting the UV lamp protection tube with automatic wiper
1.
Loosen the lamp protection tube bracket with a face spanner
and remove it (place on the holes - not on the threads!)
2.
Carefully push the UV lamp protection tube into the radiation
chamber until it reaches its stop position
3.
Push a new O-ring onto the end of the UV lamp protection
tube
4.
CAUTION!
– Check the UV lamp protection tube for
damage before fitting
– A damaged UV lamp protection tube
may not be refitted
– Ensure that the UV lamp protection tube
is sitting correctly
Ensure that the UV lamp protection tube is sitting correctly.
The UV lamp protection tube may not project out more than
13 mm and may not be offset at an angle.
5.
Screw the UV lamp protection tube bracket into the chamber
cover until hand-tight.
6.
Threaded holes
Place the screwdriver on the holes - not on
the threads. The threads could be damaged
irreparably.
Then tighten the UV lamp protection tube bracket using the
screwdriver provided, tightening angle 90° ± 5°
ð
Leak test
Following this, check the leak-tightness
of the UV system.
7.5 Assembly and connection of the UV lamp
WARNING!
Consequence: Serious injuries.
UV-C radiation is harmful to the eyes and skin
– Only start up the UV lamp
UV-C
when it is prop‐
erly installed
– Install the UV lamp into the UV system in
accordance with the regulations prior to com‐
missioning
Assembly and installation