6.5.1.2 Trend view - Lamp power
Up to 192 hours (8 days) can be written. Use the arrow keys to set
the display interval between 10 seconds, 1 hour and 1 day. This is
displayed for 0 ... 100 %, noting the minimum power. The trend
shows the power consumption (watt) of the UV lamp in %. The
maximum lamp power is 100%.
A1198
MENU
Interval
10 sec
09:51:59
24/12/2014
31/12/2014
10:23:59
100
0
0
100
Performance
HOME
1 min
Fig. 23: Trend view - Lamp power
6.5.1.3
[Data logger for 400 days]
One data set is created for every operating day in the
[data logger for 400 days]. An operating day is deemed to have
occurred if the UV lamp is operated for a minimum of 10 minutes.
After these 10 minutes, the current data for the UV sensor signal
and the electrical power to the UV lamp is written into the table with
the date. These are current operating values and not average
values. Depending on when the 10 minutes take place, the data
set can be recorded at different times. The last 401 data sets are
documented. Thereafter the oldest data sets are automatically
overwritten. The data sets are retained even after a power failure.
The data is deleted after resetting the system configuration or with
new software.
A1199
BACK
NEXT
MENU
Datalogger
Fig. 24: [Data logger for 400 days]