6.5.2.5
[Setting times - cooling, post-burning, rinse valve]
You can enter the settings for UV lamp post-burn time here. The
time for cooling is displayed purely for information purposes. The
time for cooling may only be changed after consultation with the
manufacturer.
Once the UV lamp has been switched off, the UV lamp has to cool
down before an attempt can be made to reignite it. The UV lamp
will not ignite without a cool-down. The length of the cooling down
period is pre-set and cannot be changed. If the water has to be
treated while the shut-off valve is closed and the pump is stopped,
then a post-burn time of 0 ... 9.59 minutes can be set. The default
setting is 30 seconds.
A1207
MENU
Times for cooling and disabling lamps
Time for disabling lamp(s):
Time for cooling:
Home
NEXT
Fig. 36: [Setting times - cooling, post-burning]
You can enter the time settings for the rinse valve here.
A1618
MENU
Times for rinse valve
Time for rinse valve after overheating:
Start rinse time:
Home
PREV
Fig. 37: [Times for rinse valve]
Control
44