Name
con:rbw:man
Description
Sets the RBW for manual mode.
Syntax
Con:rbw:man {0/1/2/3/}
1 100kHz
2 300kHz
Return
parameter
<NR1>
3 1MHz
Example
con:rbw:man1
Sets the RBW to 100kHz.
Name
con:rbw:mode?
Description
Returns the RBW mode.
Query
Syntax
con:rbw:mode?
auto Auto
mode
Return
parameter
manual Manual
mode
Example
con:rbw:mode?
>auto
Name
con:swt?
Description
Returns the sweep time in milliseconds.
Query
Syntax
con:swt?
Return
parameter
<NRf>
Example
con:swt?
>1500
4.3.11
Display Commands
Name
con:disp:split:upper
Description
Turns on the split window function and sweeps the top window.
Syntax
Con:disp:split:upper
Name
con:disp:split:lower
Description
Turns on the split window function and sweeps the bottom
window.
Syntax
Con:disp:split:lower
Name
con:disp:split:alt
Description
Sweeps the upper and lower windows alternatively in the split
window mode.
Syntax
Con:disp:split:lower
Name
con:disp:split:full
Description
Returns the spectrum analyser to single window mode. The
upper window is used as the active window.
Syntax
Con:disp:split:full
4-72
July 2018