• Observe electrical safety rules.
• Ensure anti-shock protection by installing
correctly.
• The appliance must be connected to the
electrical supply by a qualified electrician.
• Loose and inappropriate plug and socket
connections can make the terminal over-
heat.
• Have the clamping connections correctly
installed by a qualified electrician.
• Use strain relief clamp on cable.
• In the event of single-phase or two-phase
connection, the appropriate mains cable
of type H05BB-F Tmax 90°C (or higher)
must be used.
• If this appliance’s mains cable is damaged,
it must be replaced by a special cable (type
H05BB-F Tmax 90°C; or higher). Please
contact your local Service Force Center for
further advice.
A device must be provided in the electrical
installation which allows the appliance to be
disconnected from the mains at all poles with
a contact opening width of at least 3 mm
Suitable isolation devices include line pro-
tecting cut-outs, fuses (screw type fuses are
to be removed from the holder), earth leak-
age trips and contactors.
Assembly
600
750+1
R5
490+1
min. 55
min. 55
min. 38
min. 5
min. 20
min. 38
min. 5