Auto Sequence
Here you choose whether or not you want Egil to detect
the breaker position. You may select any breaker opera-
tion independent of the breaker position.
Time Base
Here you choose the time unit for measuring. You can
choose from milliseconds, 50 Hz cycles (equals periods)
or 60 Hz cycles. 1 cy = 20 ms at 50 Hz and 16.67 ms at
60 Hz.
Option - >
Travel Unit
Here you choose the travel unit. You can choose from mm
or inch (1 inch = 25.4 mm).
Option - End
Printouts
Here you set parameters for printouts. The maximum
length for a printout is 20 squares.
Auto Printouts
Here you choose whether or not you want a report auto-
matically printed out after every measurement. If you not
activate this function, you must press the PRINT button
after every measurement to get a printed report.
Contents
Here you can choose whether or not you want all pages
printed out or just those pages containing graphs.
Compress Time
Here you choose if you want to activate time scale
compression during the interval when something can
happen on the channels.
Supress Bounces
Here you choose whether or not you want bounces (10
ms) to be filtered when printing numeric values. This
setting does not apply to the graphic printout. Note: All
raw data is stored in Egil’s memory. Only the values that
are printed are filtered. If the function is activated, the
system gives you the time for the first contact connection
at circuit closure and the time for last contact separation at
circuit disconnection. If the function is not activated, all
registered bounces are printed.
Note!
All raw data is stored in Egil’s memory.
Only the values that are printed are
filtered. If the function is activated, the
system gives you the time for the first
contact touch at closure and the time for
last contact separation at open. If the
function is not activated, all registered
bounces are printed.
Resistor Contact
Here you choose whether or not you want Egil to measure
resistor contacts. If no, you will only see open or closed
main contacts on printouts.
Time Scale
Here you choose the time scale for the printout. The set
measure time selections vary according to the table below:
e
m
i
T
n
o
i
t
c
e
l
e
s
e
s
a
b
e
m
i
T
t
i
n
U
s
1
o
t
u
A
n
o
i
g
e
R
1
2
5
0
1
0
2
0
5
v
i
d
/
s
m
s
2
o
t
u
A
n
o
i
g
e
R
2
5
0
1
0
2
0
5
0
0
1
v
i
d
/
s
m
s
5
o
t
u
A
n
o
i
g
e
R
5
0
1
0
2
0
5
0
0
1
0
5
2
v
i
d
/
s
m
s
0
1
o
t
u
A
n
o
i
g
e
R
0
1
0
2
0
5
0
0
1
0
5
2
0
0
5
v
i
d
/
s
m
s
0
2
o
t
u
A
n
o
i
g
e
R
2
0
.
0
5
0
.
0
1
.
0
5
2
.
0
5
.
0
1
v
i
d
/
s
s
0
5
o
t
u
A
n
o
i
g
e
R
5
0
.
0
1
.
0
5
2
.
0
5
.
0
1
5
.
2
v
i
d
/
s
s
0
0
1
o
t
u
A
n
o
i
g
e
R
1
.
0
5
2
.
0
5
.
0
1
5
.
2
5
v
i
d
/
s
The table will look different if you choose the time unit
cycle instead.
Example: 1 ms/div corresponds to 0.05 cy/div at 50 Hz or
0.06 cy/div at 60 Hz.
If you choose AUTO, the interesting parts of the time
scale measurement is automatically enlarged as much as
possible.
If you choose REGION, you can enlarge a part of the
measurement around a chosen midpoint. The system
enlarges 10 squares before and 10 squares after the chosen
midpoint. The time scale is automatically set to 1/1000 of
the measure time you use. For example: 1 s corresponds to
1 ms/division.
Summary of Contents for EGIL BM-19070
Page 1: ...EGIL Breaker Analyzer User s Manual...
Page 2: ......
Page 7: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 7 E G I L...
Page 9: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 9 E G I L...
Page 15: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 1 5 E G I L...
Page 19: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 1 9 E G I L...
Page 20: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 E R 0 7 A 2 0 E G I L 5 Control panel...
Page 47: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 4 7 E G I L...
Page 49: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 4 9 E G I L...
Page 61: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 6 1 E G I L...
Page 65: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 6 5 E G I L...
Page 75: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 7 5 E G I L...
Page 78: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 E R 0 7 A 7 8 E G I L...
Page 79: ...P r o g r a m m a E l e c t r i c A B Z P B M 0 1 D R 0 7 A 7 9 E G I L...
Page 80: ...Subject to change without notice Printed matter No ZP BM01E R07A Doc BM0087JE...