Bundled Software
6-4
PL-5700 Series User’s Manual
Start-up
PLATPH [Parameter]
[
↵
]
or PLATPH -r
[
↵
]
* Parameters
-a<n>
Specifies the I/O base address of the touch panel’s SIO port.
Hexadecimal, Default: 2e8 (COM4)
n=
3f8 (COM1)
n
2f8
(COM2)
3e8
(COM3)
2e8
(COM4)
-q<n>
Specifies the interrupt level (IRQ) of the touch panel’s SIO port.
Default: 10 (COM4)
n=
4
(COM1)
3
(COM2)
11
(COM3)
10
(COM4)
-i<n>
Sets the software interrupt vector number when calling up functions.
Hexadecimal, Default: n=59
-r
Cancels the resident command.
-c <path name>
Specifies the data file containing the calibrated value obtained from
the PLCALIB.EXE application (touch panel data calibration).
When defaulted to, the PLATPH.CAL of the current directory is specified.
∗
Example platph -a2e8 -q10 -cc:\platph.cal
Normally, only “platph” is needed.
At startup, the following message will appear on the screen.
Analog Touch Panel Handler PLATPH.EXE Version X.XX
Copyright (c) 199X Digital Electronics Corporation
Stay resident.
After startup, these commands reside in memory.
• If an error is generated because, for example, there is no file created by the
PLCALIB.EXE application, the following message appears on the screen, and the
system will start up in a mode that does not calibrate data.
WARNING!! Can’t open CAL file.
Stay resident.
• Unless properly calibrated, the display and touch panel input positions may not be the same.