Malfunction
Motor does not start up
Motor hums but does not start up
Machine starts up, but becomes blocked at
low load and may switch off auto-matically
Possible cause
→ no mains voltage
→ defective cable
→ thermostat is triggered → reason:
- motor overload
- motor not getting enough air owing to
clogged ventilation apertures
→ blocked crown gear
→ defective condenser
→ extension cord is too long or its cross-
section is too small
→ socket is too far from mains connection
and the connecting wire’s cross section is
too small
Remedy
→ check fuse protection
→ have checked or replaced (electrician)
→ allow motor to cool and then find and
eliminate whatever caused the thermostat
to respond
→ switch off machine, pull plug and clean
or replace the crown gear segments
→ send machine to manufacturer or a
company designated by the manufacturer
for repairs
→ extension cord must be at least 1.5 mm²
for a maximum length of 25 m; the cross-
section of longer cables must be at least
2.5 mm²