Page 50
Practical example combination of wet timer and interval timer
A combination of the wet timer and interval timer makes sense if the interval
measurements should not start immediately after moistening of the road marking.
•
Activate the wet timer.
•
Set the wet timer time to 45 seconds.
•
Activate the internal timer.
•
Set the interval time to 5 seconds.
•
Set the interval counts to 3.
After pressing the measuring button the following procedure starts:
The first measurement will be carried out by the wet timer. Afterwards the set
number of interval counts will be carried out. So in this sample there will be a total
of 4 measurements.
The measurements can be shown on your computer using the „MappingTools”. For
this you need either to store the measuring data on a USB flash drive as described
in chapter 11.6
”Storing the measuring data on a USB mass storage device” on
page 40 or open the measuring data directly on the Zehntner ZRM 6010 as
described in chapter 12
“Data export and “MappingTools” software” as from
page 40.
Start
wet timer
HH:mm:ss
14:00:00
Measurement
Measurement
Measurement
Measurement
HH:mm:ss
14:00:45
HH:mm:ss
14:01:50
HH:mm:ss
14:01:55
HH:mm:ss
14:02:00