Chapter 3 Installation and Wiring
3-3
Creating a Panel Cut
Create the correct sized opening required to install the ST, using the installation dimensions given.
The installation gasket, installation brackets and attachment screws are all required when installing the ST.
SEE
2.5.2 Panel Cut Dimensions (Page 2-14)
•
Check that the installation panel or cabinet's surface is flat, in good condition and has no jagged
edges. Also, if desired, metal reinforcing strips can be attached to the inside of the panel, near
the Panel Cut, to increase the panel’s strength.
• Panel thickness should be from 1.6mm [0.06in.] to 10mm [0.4in.]. Decide the
panel's thickness based on the level of panel strength required.
• For easier maintenance, operation, and improved ventilation, be sure to install the
ST at least 100 mm [3.94 in.] away from adjacent structures and other equipment.
Panel
Panel Cut
Area
1.6mm[0.06in.]
to 5.0mm[0.2in.]
100
[3.94]
100
[3.94]
100
[3.94]
Unit: mm [in.]
100
[3.94]
100
[3.94]
100 [3.94]
100 [3.94]
F1
F1
F2
F2
F3
F3
F4
F4
F5
F5
F6
F6