21
Num Retry
ODV-2D > Control > Num Retry
This option allows you to set the number of times a form will be printed be-
fore the printer stops. After you clear the error message, the printer will print
the same form or the next form, depending on the setting for Max Retry Ac-
tion (see “Max Retry Action” below).
Minimum
3
Maximum
5
Factory Default
5
IMPORTANT
This setting is utilized only when Validator Action
is set to Retry Form, Stop & Retry, or
Rescan&Retry. See
.
Max Retry Action
ODV-2D > Control > Max Retry Action
This option determines what the printer will do with the current form once the
Num Retry counter has been exhausted (see “Num Retry” above)
. In the
case of any Rescan modes, only one rescan form will be attempted.
Dump Form
After you clear the fault the form will be dumped and
printing will resume with the next form.
Keep Form
After you clear the fault printing will resume with the
same form again. It will not attempt to print the next
form until the problem form has printed correctly.
Factory Default
Dump Form
IMPORTANT
This setting is utilized only when Validator Action
is set to Retry Form, Stop & Retry, Rescan Form,
Rescan&Retry, or Rescan&Stop.
.
Label Save
ODV-2D > Control > Label Save
The printer will often be printing a label when it determines that the label
printed before the immediate label was defective.
Disable
When set to disable, the printer pulls both labels back,
overstrikes them and then reprints them.
Enable
With Label Save enabled, the ODV will accept or re-
ject the label it just printed before it prints the next la-
bel. When a label is found defective, it will only over-
strike that label.
Factory Default
Disable
IMPORTANT
Label Save enabled causes a slight throughput
reduction.