Your equipment comes with a power cable that meets your local electrical code require-
ments along with the equipment. Precor commercial treadmills must be connected to a 20
amp individual branch circuit that can be shared only with one PVS.
The power cord on the treadmill is equipped with a grounding conductor and a three-pin
grounding plug. This plug must be inserted into an outlet that is properly installed and groun-
ded in accordance with all local codes and ordinances. Failure to ground the treadmill prop-
erly may void the Precor Limited Warranty.
CAUTION
: Improper connection of the grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service person if you are not
sure whether the equipment is properly grounded. DO NOT modify the plug
provided with the treadmill. If the plug does not fit the outlet, have a proper outlet
installed by a qualified electrician.
Verifying 20 Amp outlet receptacles
US and Canadian installations require 20A current rated power outlets.
You can visually identify a 20A from a 15A rated outlet receptacle by the different style outlet
sockets. Make sure the facility wall outlets are the 20A style outlet receptacles.
CAUTION
: DO NOT use 20A to 15A power cord adapters to plug the equipment
power cord into a 15A wall outlet.
20 Amp rated plugs and outlets
Country
Equipment Voltage
Receptacle/
Plug
1
Type
US & Canada
120 VAC: 50/60 Hz
Dedicated 120V/20A circuit with 5-20R NEMA
receptacle
US & Canada
240 VAC: 50/60 Hz
Dedicated 220V- 240V/20A circuit with 6-20R
NEMA receptacle
International
240VAC
IEC 320-C19 inlet supporting applicable coun-
try-specific power cord
1
Device power cord connector or electrical cable male connector that is inserted into an
electrical receptacle "outlet" (also called the plug-in).
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.