Console Power Troubleshooting
Machine powered consoles (Standard, P10, P30, P30i and P31).
1. Using a multimeter, verify that the facility outlet
AC
1
voltage is within required limits,
see
.
a. If NO, ask facility to have an electrician check the power panel circuit breaker
and outlet power.
b. If YES, continue procedure.
2. Remove the treadmill hood, switch power ON and measure the AC voltage at the
input side of the line filter. Verify that line voltage is within operating limits, see
a. If NO, replace the breaker switch.
b. If YES, continue troubleshooting.
1
Alternating Current: electric current which periodically reverses direction between positive
and negative polarity.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 250
7 Troubleshooting
System Troubleshooting Procedures