4. Use a 5/16" socket (or nut driver) to remove the Drive Motor static bleed resistor
ground wire (Orange wire). Retain part(s) and/or fastener(s) for installation.
5. Use tape or marker to make a motor base position reference mark. This reference
mark will be used to help position the replacement motor installation position.
6. Remove Drive Belt tension by loosening the four Drive Motor
1/2" hex head fasten-
ers. Remove the Drive Belt by walking the belt off the Roller pulley and then the motor
pulley.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 156
6 Replacement Procedures
Drive Motor Replacement