Model 1264 Powder Feeder
Operator’s Manual
_____________________________________________________________________________________________________________________
Issued: 04/16
Page 56
D. Gear Motor Brush Replacement
ELECTRIC SHOCK HAZARD:
Do not touch live electrical parts.
Shut down the control unit and disconnect the input power, using
proper lockout / tagout procedures before inspecting, maintaining, or
servicing the equipment. Lockout / tagout procedures consist of
locking the line disconnect switch in the open position, removing
fuses from the fuse box, or employing another disconnecting device.
D-1. Brush Removal
Gear motor brush wear varies according to the duty cycle. Inspect
brushes frequently to determine a replacement schedule.
Brush caps are on lower left and lower right side of gear motor
(item 42 in the parts list). Unscrew brush caps with an offset slot
screwdriver then pull the brushes out of brush boxes by the cap.
D-2. Brush Inspection and Cleaning
Replace brushes before they wear to less than 0.250 in. (6.35 mm)
in length. Periodically remove carbon dust accumulation with a
clean, dry, non-linting cloth. DO NOT use solvents as they can
damage the non-metallic end shield.
D-3. Brush Reassembly
To replace brushes, pull out the brush/spring assembly. Insert the
new brush assembly and screw on brush cap with offset slot
screwdriver.
D-4. Brush Cap Reassembly
1. Reconnect the drive to the power source. Test for proper
operation.
2. Proper brush seating is required for minimal level of brush
noise. Seat new brushes by running the motor with no load.