Model 1264 Powder Feeder
Operator’s Manual
_____________________________________________________________________________________________________________________
Issued: 04/16
Page 50
Table 5-1. Suggested Maintenance Schedule
Procedure
When Due
Check powder tamper assembly
Every 40 hrs. (act.
feed time)
Remove tamper assembly, inspect cam wheel, cam lifter, and nylon washer
for wear
Every 40 hrs. (act.
feed time)
Replace any parts showing excessive wear.
Every 40 hrs. (act.
feed time)
For feeders equipped with pinch valve kit, inspect pinch valve tubing for
wear or tubing taking a set (staying pinched), replace as needed
(P/N 220114)
.
Every 40 hrs. (act.
feed time)
Clean off all exterior surfaces. Including cart, pressure gauge and safety
valve.
Weekly
Check seal integrity
Weekly
Inspect all hoses for cuts, cracks or abrasion (Replace as required)
Weekly
Clean solenoid valve (and pinch valves if applicable).
Monthly
O-Ring/Seal replacement
Every 80 hrs. (act.
feed time)
Inspect motor brushes for wear (see Section 5.1.C). Replace motor if
commutator (split-ring) becomes rough, scored, or out of round.
Every 200 hrs.
(act. feed time)
Check powder carrier wheel. Replace if flatness exceeds 0.003 in. (.076
mm) or if area underneath powder grooves has wear of 0.003 in. (.076 mm).
Every 500 hrs.
(act. feed time)
Wipe Off Excess Dirt/Dust
As Needed
A. Resetting Preventive Maintenance Time Accumulator
Press Display mode selector button on left side of numeric LED display to
see Preventive Maintenance (PM) Time Accumulator value.
The PM time accumulator has the number of hours that the unit has been
in actual powder feeding operation since its last preventive maintenance
overhaul. The time recorded represents running hours only. Time spent
simply with power applied to the unit, but in a non-feeding (motor
stopped) condition, is NOT included in the count. Time on the unit is
measured in hours and tenths of hours, not hours and minutes.
Circuitry will continually monitor PM accumulation and will flash the
SERVICE LED when accumulation equals or exceeds 80 hours. This
feature reminds the user that the unit is due for a periodic overhaul of the
canister feed mechanism. This mechanism includes the wiper ring, felt
pad, o-rings, etc. Overhaul unit every 80 “feed on” hours. Overhaul unit
every 40 “feed on” hours if surface ring has been bound tight into its slot
(see Section 4-11 regarding Thorough Powder Feeder Cleaning).