Model 1264 Powder Feeder
Operator’s Manual
_____________________________________________________________________________________________________________________
Issued: 04/16
Page 33
2. Press and hold the Display MODE Selector button.
3.
While depressing the Display MODE Selector button, turn power to
the feeder ON by using the switch on the bottom of the feeder.
4.
Release the Display MODE Selector button.
The PM Time Accumulator is now reset to 0.
B. Total Run Time
Press Display mode selector button a second time to see Total Run Time.
This accumulator has the total run (feed on) hours on the machine since its
manufacture. This time count cannot be reset. This value is set to 0000 at
the factory during manufacture and increments for every run hour
accumulated. Time on the unit is measured in hours and tenths of hours,
not hours and minutes. This value shows the amount of use and wear that
unit components experience (such as the motor) that are not subject to
scheduled or periodic overhaul operations.
Press display select button a third time to return to RPM display mode
immediately. All displays will automatically return to RPM display mode
after a time-out period.
4.4
Heater Blanket On/Off Switch
Place HEATER switch in ON position to activate canister heater blanket.
Heater indicator light illuminates when switch is in ON position. Place
HEATER switch in OFF position to deactivate canister heater blanket.
HIGH TEMPERATURE HAZARD
The heater blanket typically reaches a temperature of approximately
88°C (190°F), depending on powder type, quantity, and carrier gas
flow.
4.5
Mode Switches
The Model 1264 has two mode switches, PLASMA/HVOF and
LOCAL/REMOTE. Switches can be used in any combination
(plasma/local, plasma/remote, HVOF/local, HVOF/remote) depending on
user needs. The four modes are as follows: