Page 29
5. Connect powder tube (P/N 220021) to Powder Out port on bottom of
powder feeder. Insert the tube so it bottoms out in the fitting and then
tighten the nut with the 7/16” wrench provided in the gun tool kit.
6. Connect other end of powder tube to the splitter or the gun as directed
in the gun operator’s manual.
7. Connect powder feeder power cable (P/N 5005028) to power inlet on
bottom of powder feeder.
8.
Connect other end of powder feeder power cable to 110 VAC power
source. The powder feeder is now operational.
9.
Verify that the canister lid is secured and apply carrier gas to the
powder feeder. Check for leaks.
EXPLOSION HAZARD:
Never use an explosive gas as the carrier
gas.
VIOLENT FAILURE HAZARD:
improper gas pressure may
damage equipment, impair performance, and/or cause injury. Do not
operate this powder feeder above 90 psi (6.2 bar) or 60 psi (4.1 bar)
if pinch valve kit is installed. Powder feed repeatability and operator
safety depend on correct pressure and flow.