background image

4

5

TECHNICAL CHARACTERISTICS

DZ RIO 400

DZ RIO R 500

DZ RIO R 700

DZ RIO 300 

CUSTOM MONO

DZ RIO 350 

MONO SP

TYPE OF OPERATOR

SLIDING

SLIDING

SLIDING

SLIDING

SLIDING

MODEL

SINGLE-PHASE

SINGLE-PHASE

SINGLE-PHASE

SINGLE-PHASE

SINGLE-PHASE

RATED VOLTAGE

127V / 220V

127V / 220V

127V / 220V

127V / 220V

127V / 220V

NOMINAL FREQUENCY

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz

RATED POWER

370 W / 515 W

300 W / 286 W

400 W / 450 W

250 W / 260 W

300 W / 480 W

ENGINE ROTATION

1740

1740

1740

1740

1740

NOMINAL CHAIN

3,1 A / 2,25 A

3,05 A / 2,35 A

3,1 A / 2,1 A

2 A / 1,5 A

2 A / 2 A

REDUCTION

1:23

1:23

1:23

1:23

1:23

LINEAR SPEED

13,3m/min ( Z14)

17,1 m/min (Z18)

13,3m/min ( Z14)

17,1 m/min (Z18) 

13,3m/min ( Z14)

17,1 m/min (Z18)

13,3m/min ( Z14)

17,1 m/min (Z18)

22m/min ( Z22)

MANEUVERS

30

40

60

20

30

DEGREE OF PROTECTION

IPX4

IPX4

IPX4

IPX4

IPX4

TEMPERATURE RANGE

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

TYPE OF INSULATION

Class B, 130º C

Class B, 130º C

Class B, 130º C

Class B, 130º C

Class B, 130º C

LIMIT SWITCH

Analog / Digital

Analog / Digital

Analog / Digital

Analog / Digital

Analog / Digital

MAX. MASS FROM THE LEAF 

OF THE GATE

400 Kg

500 Kg

700 Kg

300 Kg

350 Kg

MAX. DIMENSION OF THE 

GATE

HEIGHT = 2.5 m

LENGTH. = 3.0 m

HEIGHT = 2.5 m

LENGTH. = 3.0 m

HEIGHT = 2.5 m

LENGTH. = 3.0 m

HEIGHT = 2.5 m

LENGTH. = 3.0 m

HEIGHT = 2.5 m

LENGTH. = 3.0 m

DZ RIO 350 

JETFLEX

DZ RIO 500 

JETFLEX

DZ RIO R 600 

JETFLEX

DZ RIO R 800 

JETFLEX 

TYPE OF OPERATOR

SLIDING

SLIDING

SLIDING

SLIDING

MODEL

THREE PHASE

THREE PHASE

THREE PHASE

THREE PHASE

RATED VOLTAGE

127V / 220V

127V / 220V

127V / 220V

127V / 220V

NOMINAL FREQUENCY

60 Hz

60 Hz

60 Hz

60 Hz

RATED POWER

340 W / 280 W

330 W / 270 W

370 W / 310 W

280 W / 230 W

ENGINE ROTATION

5800

5800

5800

5800

NOMINAL CHAIN

2,4 A / 2,5 A

3,4 A / 2,0 A

3,6 A / 2,1 A

2,8 A / 1,6 A

REDUCTION

1:23

1:23

1:23

1:23

LINEAR SPEED

33 m/min ( Z14)

42,9 m/min (Z18) 

33 m/min ( Z14)

42,9 m/min (Z18) 

33 m/min ( Z14)

42,9 m/min (Z18) 

33 m/min ( Z14)

42,9 m/min (Z18) 

MANEUVERS

30

40

50

60

DEGREE OF PROTECTION

IPX4

IPX4

IPX4

IPX4

TEMPERATURE RANGE

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

TYPE OF INSULATION

Class B, 130° C

Class B, 130° C

Class B, 130° C

Class B, 130° C

LIMIT SWITCH

HYBRID

HYBRID

HYBRID

HYBRID

MAX. MASS FROM THE LEAF 

OF THE GATE

350 Kg

500 Kg

600 Kg

800 Kg

MAX. DIMENSION OF THE 

GATE

HEIGHT = 2.5 m

LENGTH. = 3.0 m

HEIGHT = 2.5 m

LENGTH. = 3.0 m

HEIGHT = 2.5 m

LENGTH. = 3.0 m

HEIGHT = 2.5 m

LENGTH. = 3.0 m

DZ RIO PREDIAL 700

DZ RIO PREDIAL 800 

JETFLEX

TYPE OF OPERATOR

SLIDING

SLIDING

MODEL

SINGLE-PHASE

THREE PHASE

RATED VOLTAGE

127V / 220V

127V / 220V

NOMINAL FREQUENCY

60 Hz

60 Hz

RATED POWER

400 W / 450 W

280 W / 230 W

ENGINE ROTATION

1740

5800

NOMINAL CHAIN

3,1 A / 2,1 A

2,8 A / 1,6 A

REDUCTION

1:23

1:23

LINEAR SPEED

17,1 m/min (Z12) 

42,9 m/min (Z12) 

MANEUVERS

60

70

DEGREE OF PROTECTION

IPX4

IPX4

TEMPERATURE RANGE

-5° C / +50° C

-5° C / +50° C

TYPE OF INSULATION

Class B, 130° C

Class B, 130° C

LIMIT SWITCH

Analog

HYBRID

MAX. MASS FROM THE LEAF 

OF THE GATE

700 Kg

800 Kg

MAX. DIMENSION OF THE 

GATE

HEIGHT = 2.5 m

LENGTH. = 3.0 m

HEIGHT = 2.5 m

LENGTH. = 3.0 m

Summary of Contents for DZ RIO

Page 1: ...l manual P30454 04 2022 Rev 0 Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito Industrial Gar a SP CEP 17406 200 Brasil CNPJ 52 605 821 0001 5...

Page 2: ...equired on the equipment identification label Do not turn on the mains until the installation maintenance is completed Make the electrical connections of the command board always with the power grid t...

Page 3: ...SLIDING SLIDING SLIDING SLIDING MODEL THREE PHASE THREE PHASE THREE PHASE THREE PHASE RATED VOLTAGE 127V 220V 127V 220V 127V 220V 127V 220V NOMINAL FREQUENCY 60 Hz 60 Hz 60 Hz 60 Hz RATED POWER 340 W...

Page 4: ...use must be a flexible cable 3 x 0 75 mm 500 V according to the NBR standard NM 247 5 The power conductor of a product for external use must be a flexible cable 3 x 0 75 mm 500 V as per the standard I...

Page 5: ...The system that uses a straight section Picture A angle presents greater friction and consequently greater wear The circular section Picture B allows for better gate displacement and less friction for...

Page 6: ...EAF SIDE VIEW CONCRETE BASE 4th Step Pre align the operator to the gate positioning the rack over the gear and leaning the set against the gate Then mark the fixing holes in the floor or concrete base...

Page 7: ...mm GAP 2 mm 300 OR 400 mm 300 OR 400 mm 8th Step If the gate leaf is warped provide wedges to ensure rack alignment There are cases where the rack will need to extend the length of the leaf In this ca...

Page 8: ...REED This magnet will act as a closing limit switch MAGNET SUPPORT MAGNET SUPPORT REED SUPPORT UPPER VIEW GATE CLOSING 2nd Step Fully open the gate and place the other magnet support on the rack faci...

Page 9: ...maintenance it is necessary to completely disconnect the electrical network DEFECTS PROBABLE CAUSES CORRECTIONS Motor does not start does not move A Power off B Open blown fuse C Locked gate D Defecti...

Reviews: