background image

16

17

3rd Step:

 Start the engine and observe if the REED’s are shutting down correctly.

If necessary, invert the board connector.

Once the magnet supports are fixed, make the final adjustments, moving them to 

the right or to the left, according to the desired adjustment.

4th Step: 

To finish installing the operator, it is mandatory, before it works, to screw 

the fairing with 2 screws 3.5 x 16 mm (available in the kit).

SUPPORT ADJUSTMENT

COMMAND BOARD:

Check the label attached to the product 

(according to the model on the side) 

which is the board operator. Once this is 

done, consult the manual board which 

is available for download at 

www.ppa.

com.br

 and perform all connections 

and settings.

Lot:

Code:

Model:

Reduction:

Technology:

Voltage:

Board:

Size:

Mounting:

Fairing:

Gear:

MAINTENANCE 

 

In the table below, some PROBLEMS will be mentioned — DEFECTS, PROBABLE 

CAUSES AND CORRECTIONS — that may occur in your Operator. Before any 

maintenance, it is necessary to completely disconnect the electrical network.

DEFECTS

PROBABLE CAUSES

CORRECTIONS

Motor does not 

start / does not 

move

A) Power off

B) Open / blown fuse

C) Locked gate

D) Defective limit switch

A) Make sure the electrical network 

is connected correctly

B) Replace fuse with same 

specification

C) Make sure there is no object 

blocking the gate operation

D) Replace the limit switch system 

(analog and/or digital)

Engine blocked

A) Inverted motor connection

B) Locked gate or trigger

A) Check motor wires

B) Put in manual mode and check 

separately

Electronics board 

does not accept 

command

A) Blown fuse

B) Mains disconnected (power)

C) Defect in remote control 

unloaded

D) Transmitter range (remote 

control)

A) Replace the fuse

B) Connect the network (power)

C) Check and replace battery

D) Check the position of the receiver 

antenna and, if necessary,

reposition it to ensure reach

Motor only rotates 

to one side

A) Inverted motor wires

B) Inverted limit switch system

C) Defect in command board

A) Check motor connection

B) Invert the limit switch connector 

(analog and/or digital)

C) Replace the command board

Summary of Contents for DZ RIO

Page 1: ...l manual P30454 04 2022 Rev 0 Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito Industrial Gar a SP CEP 17406 200 Brasil CNPJ 52 605 821 0001 5...

Page 2: ...equired on the equipment identification label Do not turn on the mains until the installation maintenance is completed Make the electrical connections of the command board always with the power grid t...

Page 3: ...SLIDING SLIDING SLIDING SLIDING MODEL THREE PHASE THREE PHASE THREE PHASE THREE PHASE RATED VOLTAGE 127V 220V 127V 220V 127V 220V 127V 220V NOMINAL FREQUENCY 60 Hz 60 Hz 60 Hz 60 Hz RATED POWER 340 W...

Page 4: ...use must be a flexible cable 3 x 0 75 mm 500 V according to the NBR standard NM 247 5 The power conductor of a product for external use must be a flexible cable 3 x 0 75 mm 500 V as per the standard I...

Page 5: ...The system that uses a straight section Picture A angle presents greater friction and consequently greater wear The circular section Picture B allows for better gate displacement and less friction for...

Page 6: ...EAF SIDE VIEW CONCRETE BASE 4th Step Pre align the operator to the gate positioning the rack over the gear and leaning the set against the gate Then mark the fixing holes in the floor or concrete base...

Page 7: ...mm GAP 2 mm 300 OR 400 mm 300 OR 400 mm 8th Step If the gate leaf is warped provide wedges to ensure rack alignment There are cases where the rack will need to extend the length of the leaf In this ca...

Page 8: ...REED This magnet will act as a closing limit switch MAGNET SUPPORT MAGNET SUPPORT REED SUPPORT UPPER VIEW GATE CLOSING 2nd Step Fully open the gate and place the other magnet support on the rack faci...

Page 9: ...maintenance it is necessary to completely disconnect the electrical network DEFECTS PROBABLE CAUSES CORRECTIONS Motor does not start does not move A Power off B Open blown fuse C Locked gate D Defecti...

Reviews: