background image

User manUal

e-Gate sWG-12V

 12V Articulated Arm Swing Gate Operators

FOR

Summary of Contents for e-Gate SWG-12V

Page 1: ...User manual e Gate SWG 12V 12V Articulated Arm Swing Gate Operators FOR ...

Page 2: ...r automatic gate operator 1 how the controls work 2 how to manually release the gate 3 maintenance 4 wiring diagram for battery 5 what happens if there is a power cut 5 changing the remote control battery 6 trouble shooting 7 ...

Page 3: ... have a seperate gate for Pedestrian entry please use this if you are on foot rather than the Automatic Vehicle Gate In the event you sell the property make sure the new owners have a copy of these instructions If you lose the instructions they can be downloaded from www grantsautomation com au If a photocell is used this will prevent the gate from closing on a vehicle If the gate is closing and t...

Page 4: ...a second and then go off Test the new remote to see if it opens the gate To get Button B to work firstly press buttons A and D together on a working re mote control and the operator should start beeping now press button B on the new remote control and the operator should respond as before and this button should now work To get buttons C or D to open the gate part way for pedestri an entry press bu...

Page 5: ...lly release the gate Using a Spanner Loosen the large bolt holding the Arm to the Operator Then push down on the arm to release it from it s collar Do not remove the bolt completely The Gate can now be opened by Hand ...

Page 6: ... Open the cover every year or so and check the operator is clean inside and that the output gears are greesed These are exposed when the cover is off and require only a small amount of normal automative greese which can be wiped on with a finger if it s a little dry Spray around the operator with Baygon Surface Spray to deter any bugs DO NOT spray anything on the electronic circuit board The Batte...

Page 7: ... the gate is fully open it may require a couple of presses of the remote control to start closing If Limit Switches are Not used the operator will also operate per normal although if the gate is fully open it will require a couple of presses of the remote control and if partly open it will start to open but will not know where the open stop is so will reverse back closed and runn slow until it fin...

Page 8: ...ily fall out and is a little fiddly to get back in Once the new battery is in place re fit the back half in reverse order to how it was removed and replace the screw Undo the screw in the back of the remote control with a small Phillips screw driver then lift the back half up as far as you can slide it forward to free it from the front half without having to remove the key ring Then seperate the b...

Page 9: ...r running very slowly the solar panel may not be getting enough sun to keep the battery charged Check the Solar Panel is getting adaquate sunlight and cabling is in good condition An extra solar panel and storage battery may be required and or the solar panel repositioned so it gets more sun Remote control range drops some times most likely caused by interference from some other device in the area...

Reviews: