32
Motor blocked
A) Inverted motor
connection
A) Check the motor wires
B) Locked gate or
motor
B) Manually unlock the
operator and check
individually the gate
movement and the motor
operation
Electronic board does
not accept command
A) Burned fuse
A) Replace the fuse
B) Power grid off
(power)
B) Connect the power gird
(power)
C) Low battery on
the remote control
C) Check and replace the
battery
D) Transmitter
range (remote
control)
D) Check the position of
the receiver antena and, if
necessary, reposition it to
improve the range.
Motor only turns to one
side
A) Inverted motor
wires
A) Check the motor
B) Inverted limit
switch system
B) Invert the limit switch
connector (analog and / or
digital)
C) Defect in the
commanc board
C) Replace the board
The gate does not
correspond to the path
of the place where
the operator has been
installed (it brakes before
it reaches the stop or
slams when closing).
The recorded path
is different from the
place where the
operator has been
installed.
Press both ‘+’ and ‘-’ buttons
at the
same time and keep them
pressed until ‘OSC’ LED lights
up.
Gate remains open
and when it receives
commands to open, it
closes.
Travel recognizing
was not performed
correctly.
Refer to item: First operation
after installation (gate travel
recognition)
LED “OSC” flashes
Quickly and the motor
Turns off.
Current sensor
activated. this may
happen when
the motor has a
malfunction.
Check the stator resistance.
check the motor current (it
must be less than 3A rms
with 5A rms peak current - 2s
maximum).