24
25
Programming Functions Table:
Function Description
“_” or “REC”
(DIP 1)
1 2 3 4 5 6 7 8
ON
FUNCTION SELECTOR / RECORD OR DELETE TRANSMITTERS
(TX)
When combined with other DIPs, it enables the edit of the under-
lined parameters.
When only the DIP 1 is activated, the board is ready to record or
delete (TX) transmitters.
Record TX:
press the desired transmitter button after you have acti-
vated this DIP, note that the OSC LED flashes fast if are receiving the
signal and then press the (+) button on the board to record. Note
that the OSC LED lights up when receive a sinal already recorded
on the board.
Delete
: To delete the RF transmitters stored in the memory, press
the Triflex (-) button and the (+) button simultaneously for 10 se-
conds, note that the OSC LED will blink every 1s and after 10s the
LED OSC for the count at that time all recorded transmitters have
been deleted.
“PTA”
(DIP 1 and 2)
1 2 3 4 5 6 7 8
ON
SEMIAUTOMATIC FUNCTION / PAUSE TIME IN THE
AUTOMATIC MODE
Press “+” button for incrementing the pause time.
Press “-“ button for decrementing the pause time.
Gate
: Increases or decreases time by two seconds (2s) from zero
(0s) two hundred and forty seconds (240s), when the zero value is
selected, the operator becames semiautomatic.
Barrier
: Increases or decreases time by one second (1s) from zero (0s)
to two hundred forty seconds (240s), when the zero value is selected
the operator becomes semiautomatic.
“CLS”
(DIP 1 and 3)
1 2 3 4 5 6 7 8
ON
CLOSING END OF TRAVEL ZONE
Increases or decreases the distance in which the operator starts to
slow down when closing.
“OLS”
(DIP 1 and 4)
1 2 3 4 5 6 7 8
ON
OPENING
END OF TRAVEL ZONE
Increases or decreases the distance in which the operator starts to
slow down when opening.
“GSS”
(DIP 1 and 5)
1 2 3 4 5 6 7 8
ON
GATE: HOW TO ADJUST THE GAP BETWEEN GATE AND ITS
MECHANICAL STOP
If necessary, the space between the stop and the gate can be
adjusted when the operator completes the closing or opening
cycle. It can be closer or far from the stop.
The minimum value of 0 (LED flashes), increment and decrement
from 1 to the maximum value of 10 (LED lit).
Important: To test the changes, it is necessary to operate the
gate once, so that the operator system performs an opening and
closing cycle.
BARRIER: SET THE BARRIER TO CLOSE AUTOMATICALLY WHEN
ENERGIZED
Press the (-) button to turn off (LED flashing) the function or the (+)
button to activate it (LED on).
When this function is enabled, the barrier automatically initiates
the closing movement after a power-up. If there is any command
to open, for example, FOT, BOT, ABR and etc., the gate initiates an
opening movement.
Also, this function CONFIGURES THE “LIGHT” AND “LOCK” OUTPUTS
TO OPERATE AS “CLOSING BARRIER” AND “OPENING BARRIER”
SIGNALING, RESPECTIVELY.
“MPA”
(DIP 1 and 6)
1 2 3 4 5 6 7 8
ON
GATE: HOW TO DECREASE OR INCREASE MOTOR STRENGTH
DURING TRAVEL RECOGNITION.
If necessary, it is possible to decrease the motor force during the travel
recognition, for example, to avoid that the rack bar breaks.
It is also possible to increase the strength, if necessary.
Press the ‘+’ button to increase the strength and the ‘-’ button to
decrease it.
The minimum level is 40% (LED blinking) and it is increased by four
levels at a time (4%) up to the maximum 100% level (LED lit).
“PCF”
(DIP 1 and 7)
1 2 3 4 5 6 7 8
ON
GATE AND BARRIER: ENABLE PHOTOCELL ‘FOLLOWER MODE’
In some facilities, such as a comdominium, it is necessary that the gate
closes automatically as soon as the vehicle gets out from the gate path.
In order to do so, there must installed a photocell and the “follower” (aka
mirrored) function must be enabled.
Press the ‘+’ to enable it and to include the period of time before the
automatic closing.
The minimum value is zero (0 – LED blinking) and it is increased by one
second at a time (1) up to its maximum 60-second value (LED lit).
Example:
LED blinking (function disabled). When pressing the
‘+’ button once, the LED is turned off and the “follower” mode is
enabled. The pause time before the automatic closing starts is zero
(0) second. If the button is pressed once more, the pause now is one
(1) second, and so on, up to sixty (60) seconds, when the LED lits.