Turn on the remaining UPS according to the previous section.   
 

 

Warning: 

(Only for the parallel system) 

 

Before turning on the parallel system to activate inverter, make sure that all unit’s maintenance switch at 

the same position. 

 

When parallel system is turned on, please do not operate the maintenance switch of any unit. 

 

Please Do NOT enable the ECO mode in parallel system.   

 

3-6. Fault Code 

Fault code 

Fault event 

Icon 

Fault code  Fault event 

Icon 

01 

Bus start failure 

None 

42 

DSP communication failure 

None 

02 

Bus over 

None 

43 

Overload 

None 

03 

Bus under 

None 

46 

Incorrect UPS setting 

None 

04 

Bus unbalance 

None 

47 

MCU communication failure 

None 

06 

Converter over current 

None 

48 

Two DSP firmware versions 

are incompatible in parallel 

system. 

None 

11 

Inverter soft start failure 

None 

60 

Bypass phase short circuited 

None

 

12 

High inverter voltage 

None 

61 

Bypass SCR short circuited 

None 

15 

Inverter B output(line to 

neutral) short circuited 

None

 

62 

Bypass SCR open circuited 

None 

16 

Inverter C output(line to 

neutral) short circuited 

None

 

63 

Voltage waveform abnormal 

in A phase 

None 

17 

Inverter A-B output (line 

to line) short circuited 

None

 

64 

Voltage waveform abnormal 

in B phase 

None 

18 

Inverter B-C output (line 

to line) short circuited 

None

 

65 

Voltage waveform abnormal 

in C phase 

None 

19 

Inverter C-A output (line 

to line) short circuited 

None

 

66 

Inverter current detect 

abnormal 

None 

1A 

Inverter A negative power 

fault 

None

 

67 

Bypass O/P short circuited 

None 

1B 

Inverter B negative power 

fault 

None 

68 

Bypass O/P line to line short 

circuited 

None 

1C 

Inverter C negative power 

fault 

None 

69 

Inverter SCR short circuited 

None 

21 

Battery SCR short circuited  None 

6C 

BUS voltage drops too fast 

None 

 

23 

 

Inverter relay circuited 
open 

None 

6D 

Current error value detect 

None 

24 

Inverter relay short 

circuited 

None 

6E 

SPS power error 

None 

25 

Line wiring fault 

None 

6F 

Battery polarity reverse 

None 

31 

Parallel communication 

failure 

None 

71 

PFC IGBT over-current in A 

phase 

None 

32 

The host signal failure 

None 

72 

PFC IGBT over-current in B 

phase   

None 

33 

Synchronous signal failure  None 

73 

PFC IGBT over-current in C 
phase   

None 

34 

Synchronous trigger signal 

failure 

None 

74 

INV IGBT over-current in A 

phase 

None 

35 

Parallel communication 

loss 

None 

75 

INV IGBT over-current in B 

phase   

None 

36 

Parallel output current 
unbalance 

None 

76 

INV IGBT over-current in C 
phase 

None 

41 

Over temperature 

None 

77 

LCD&MCU communication 

failed 

None 

 
 

Summary of Contents for VFI 10KL CPG PF1 3/3

Page 1: ...PowerWalker VFI 10K 80K CPG PF1 3 3 Uninterruptible Power Supply System Version 1 0 1...

Page 2: ...E 26 5 2 MAINTENANCE 26 6 SPECIFICATIONS 27 Please comply with all warnings and operating instructions in this manual This equipment should only be installed serviced and maintained by qualified perso...

Page 3: ...n the final installation phase connect grounding wire to the external UPS battery cabinets or appropriate grounding terminals The UPS can be installed only by qualified maintenance personnel An approp...

Page 4: ...g conductor cable on the UPS or the building wiring terminals under any circumstance The UPS system features its own internal current source batteries The UPS output sockets or output terminal blocks...

Page 5: ...lowing chapter 2 1 Unpacking and Inspection Unpack the package and check the package contents The shipping package should contain One UPS One user manual One monitoring software CD option please check...

Page 6: ...4 2 2 Wiring Terminal View Diagram 1 10K 15K 20K L Diagram 2 10K 15K 20K L Rear Panel DUAL Rear Panel Diagram 3 10K 15K 20K L Diagram 4 10K 15K 20K L Input Output Terminal DUAL Input Output Terminal...

Page 7: ...5 Diagram 5 30K L Rear Panel Diagram 6 40K L Rear Panel Diagram 7 30K L 40K L Dual Input Input Output Terminal...

Page 8: ...6 Diagram 8 60KL front view Diagram 9 80KL front view with door open with door open Diagram 10 60KL 80KL Input Output Terminal...

Page 9: ...e as the input power source for the UPS as its rated current is less than the UPS s maximum input current The receptacle may be damaged and destroyed 2 Switch off the mains switch in the building befo...

Page 10: ...15K L 20K L Terminal block wiring diagram for 10K L 15K L 20K L Terminal block wiring diagram for 30K L 40K L Terminal block wiring diagram for 30K L 40K L Terminal block wiring diagram HV 60KL 80KL T...

Page 11: ...ion to the rated battery voltage marked on the rear panel If you want to change the numbers of the battery pack please make sure you modify the setting simultaneously The Connection with wrong battery...

Page 12: ...gram of parallel system for 10K L 15K L 20K L a Wiring diagram of parallel system for 10K L 15K L 20K L Wiring diagram of parallel system for 30K L 40K L Wiring diagram of parallel system for 30K L DU...

Page 13: ...iring diagram of parallel system for 60KL 80KL 2 5 Software Installation For optimal computer system protection install UPS monitoring software to configure UPS shutdown operation Please download the...

Page 14: ...er into the sub screen MAIN Initializing INFORMATION CONTROL SETTING DATA LOG MEASURE ON OFF UPS BATTERY TEST MUTE ALL MEASURE1 MEASURE2 MEASURE3 BASIC ADVANCE BASIC1 BASIC2 ELECTRICAL BATTERY MISCELL...

Page 15: ...n 0 0 Screen 1 0 Control screen with common control operation Screens 1 1 1 to start and stop the unit through the control panel Enter YES to turn on or turn off UPS And screen will jump to main scree...

Page 16: ...attery test are Battery testing The battery test is running Battery Test failed The battery test has been failed Screen 1 1 3 to order cancel mute of UPS Enter YES to make UPS mute Press BACK or No ic...

Page 17: ...hases to neutral for three phase or single phase units 0 1V Bypass voltages phase to phase units 0 1V Bypass voltages phases to neutral for three phase or single phase units 0 1V Output voltages phase...

Page 18: ...can program the time hh mm ss hours minutes seconds and the date dd mm yy day month year You can select the display language between the available options it may vary You can select input source Line...

Page 19: ...level an authorized password will be required to modify some advanced parameters Screens 3 1 2 Advance settings Screens 3 1 2 1 You can select the output voltage between the following options 208V 220...

Page 20: ...an select the ECO frequency range The range of frequency goes from 46Hz to 54Hz when UPS is 50Hz system and goes from 56 Hz to 64 Hz when UPS is 60Hz system You can select Whether UPS is enable or dis...

Page 21: ...rmation To modify the rated values on the screens it is necessary to introduce the Password on the previous screen 3 0 otherwise they only will be able to be visualized The basic information shows UPS...

Page 22: ...ere are all the possible alarms displayed in the display LCD 3 3 Audible Alarm Description Buzzer status Muted UPS status Bypass mode Beeping once every 2 minutes Yes Battery mode Beeping once every 4...

Page 23: ...f the UPS is overload the buzzer will beep twice every second 4 When the UPS is overload please remove some loads immediately It is recommended to have the total loads connected to the UPS less than 8...

Page 24: ...ns that there are problems for UPS operation Users can get the warning indicator from LCD panel Please check the trouble shooting table in Chapter 4 for details 2 Some warning alarms can t be muted un...

Page 25: ...er the UPSs enter to Battery mode and add to the parallel system d If you have the third UPS follow the same procedure of c Then the parallel system is complete If more detail information is needed pl...

Page 26: ...e short circuited None 64 Voltage waveform abnormal in B phase None 18 Inverter B C output line to line short circuited None 65 Voltage waveform abnormal in C phase None 19 Inverter C A output line to...

Page 27: ...ed position to disable the EPO function The warning code 01 The external or internal battery is incorrectly connected Check if all batteries are connected well The warning code 09 UPS is overload Remo...

Page 28: ...acks which are potentially dangerous Before carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the te...

Page 29: ...7 Ah 12 V 9 Ah 12 V 7 Ah 12 V 9 Ah N A Numbers 10 10 pcs 16 16 pcs x 2 strings Recharge Time 9 hours recover to 90 capacity Charging Current max 2 0 A 10 Recommended 1 0 12 0A Adjustable Charging Vol...

Reviews: