31
AUDIBLE PRE - MOVE WARNING
By moving Dipswitch #4
to the
“ON”
position the option of a
3 second Audible Warning, before gate movement, may be
selected.
AUXILIARY CIRCUIT FOR USE WITH GATE LOCKS,
WARNING LIGHTS, ETC
An auxiliary 24 VAC power circuit, for use with a 24V
control relay, has been provided. This circuit will be
activated just prior to gate movement and will
continue to be active until the gate stops. It may be
used to control a gate lock, activate warning lights
and solenoid controlled devices or any other system
required during this time interval. Two control options
are available.
CO
M
CO
M
CO
M
24
V
AC
24
V
AC
AL
T
RD
O
OP
N
CR
O
FR
E
OP
N
CL
O
ST
O
CO
M
CO
M
CO
M
OP
N
PH
O
CL
O
PH
O
SH
W
RE
V
OP
N
ED
G
CL
O
ED
G
MS
T
OP
N
MS
T
CL
O
CO
M
CO
M
CO
M
OPEN
PUSH
FREE
EXT
ALT
RADIO
OPN/
CLO
RADIO
OPEN
CLOSE
PUSH
STOP
PUSH
CLOSE
PHOTO
OPEN
PHOTO
LD18
LD10
LD11
LD12
LD15
LD14
LD16
LD17
LD13
OPEN
CLOSE
STOP
OPEN
CLOSE
FORCE
ADJUSTMENT
AUTO
RECLOSE
TIMER
OFF
MAX
MID
LIMIT
REV
LOOP
OPN
EDGE
CLO
EDGE
RH OPN
LH CLO
LIMIT
RH CLO
LH OPN
LIMIT
MOTOR
OPEN
MOTOR
CLOSE
SHADOW
LOOP
LD19
LD2
LD3
LD4
LD5
LD6
LD8
LD9
LD7
1 2 3 4 5
POWER
LD1
P3
P4
TB1
TB2
U1
U2
U4
1 2 3 4 5
ON
OFF
1 2 3 4 5
OFF
ON
ON
OFF
Audible
Pre-move Warning
Option
32
OPTION #1 – POWER REMOVED DURING GATE MOVEMENT
Below is a diagram showing the connection of a
device, such as a magnetic gate lock,
requiring the
removal of power during the gate movement.
OPTION #2 – POWER SUPPLIED DURING GATE MOVEMENT
The following diagram shows the connection of a device,
such as a solenoid operated gate lock,
requiring power
during gate movement.
CO
M
CO
M
CO
M
24
V
AC
24
V
AC
AL
T
RD
O
OP
N
CR
O
FR
E
OP
N
CL
O
ST
O
CO
M
CO
M
CO
M
OP
N
PH
O
CL
O
PH
O
SH
W
RE
V
OP
N
ED
G
CL
O
ED
G
MS
T
OP
N
MS
T
CL
O
CO
M
CO
M
CO
M
OPEN
PUSH
FREE
EXT
ALT
RADIO
OPN/
CLO
RADIO
OPEN
CLOSE
PUSH
STOP
PUSH
CLOSE
PHOTO
OPEN
PHOTO
LD18
LD10
LD11
LD12
LD15
LD14
LD16
LD17
LD13
OPEN
CLOSE
STOP
OPEN
CLOSE
FORCE
ADJUSTMENT
AUTO
RECLOSE
TIMER
OFF MAX
MID
LIMIT
REV
LOOP
OPN
EDGE
CLO
EDGE
RH OPN
LH CLO
LIMIT
RH CLO
LH OPN
LIMIT
MOTOR
OPEN
MOTOR
CLOSE
SHADOW
LOOP
LD19
LD2
LD3
LD4
LD5
LD6
LD8
LD9
LD7
1 2 3 4 5
POWER
LD1
P3
P4
TB1
TB2
U1
U2
U4
To Gate Locks,
Warning Lights, Ect.
R
WH
R
Y
GY
BK
WH
GND (Common)
24 VAC
From
Transformer
Power In
To Aux. Device
Relay With
24 VAC Coil
WH
Y
BR
WH
N.O.
N.C.
Power leg
Neutral
Aux. Circuit Using
Normally Open
Control Relay
CO
M
CO
M
CO
M
24
V
AC
24
V
AC
AL
T
RD
O
OP
N
CR
O
FR
E
OP
N
CL
O
ST
O
CO
M
CO
M
CO
M
OP
N
PH
O
CL
O
PH
O
SH
W
RE
V
OP
N
ED
G
CL
O
ED
G
MS
T
OP
N
MS
T
CL
O
CO
M
CO
M
CO
M
OPEN
PUSH
FREE
EXT
ALT
RADIO
OPN/
CLO
RADIO
OPEN
CLOSE
PUSH
STOP
PUSH
CLOSE
PHOTO
OPEN
PHOTO
LD18
LD10
LD11
LD12
LD15
LD14
LD16
LD17
LD13
OPEN
CLOSE
STOP
OPEN
CLOSE
FORCE
ADJUSTMENT
AUTO
RECLOSE
TIMER
OFF MAX
MID
LIMIT
REV
LOOP
OPN
EDGE
CLO
EDGE
RH OPN
LH CLO
LIMIT
RH CLO
LH OPN
LIMIT
MOTOR
OPEN
MOTOR
CLOSE
SHADOW
LOOP
LD19
LD2
LD3
LD4
LD5
LD6
LD8
LD9
LD7
1 2 3 4 5
POWER
LD1
P3
P4
TB1
TB2
U1
U2
U4
To Gate Locks,
Warning Lights, Ect.
R
WH
R
Y
GY
BK
WH
GND (Common)
24 VAC
From
Transformer
Power In
To Aux. Device
Relay With
24 VAC Coil
WH
Y
BR
WH
N.O.
N.C.
Power leg
Neutral
Aux. Circuit Using
Normally Closed