27
CO
M
CO
M
CO
M
24V
AC
24V
AC
AL
T
RD
O
OP
N
CR
O
FR
E
OP
N
CL
O
ST
O
CO
M
CO
M
CO
M
OP
N
PH
O
CL
O
PH
O
SH
W
RE
V
OP
N
ED
G
CL
O
ED
G
MS
T
OP
N
MS
T
CL
O
CO
M
CO
M
CO
M
OPEN
PUSH
FREE
EXT
ALT
RADIO
OPN/
CLO
RADIO
OPEN
CLO SE
PUSH
STO P
PUSH
CLO SE
PHOT O
OPEN
PHOT O
LD1 8
LD1 0
LD1 1
LD1 2
LD1 5
LD1 4
LD1 6
LD1 7
LD1 3
OPE N
CLOS E
STOP
OPE N
CLOSE
FORCE
ADJUSTM ENT
AUTO
RECLOSE
TIME R
OFF
MAX
MID
LIMIT
REV
LO OP
OPN
EDGE
CLO
EDGE
RH OPN
LH CLO
LIMIT
RH CLO
LH OPN
LIMIT
MOTO R
OPEN
MOTO R
CLO SE
SHADOW
LO OP
LD19
LD2
LD3
LD4
LD5
LD6
LD8
LD9
LD7
1 2 3 4 5
POW ER
LD1
P3
P4
TB 1
TB 2
U1
U2
U4
1 2 3 4 5
ON
OFF
1 2 3 4 5
Master
Slave
ON
OFF
CO
M
CO
M
CO
M
24V
AC
24V
AC
AL
T
RD
O
OP
N
CR
O
FR
E
OP
N
CL
O
ST
O
CO
M
CO
M
CO
M
OP
N
PH
O
CL
O
PH
O
SH
W
RE
V
OP
N
ED
G
CL
O
ED
G
MS
T
OP
N
MS
T
CL
O
CO
M
CO
M
CO
M
OPEN
PUSH
FREE
EXT
ALT
RADIO
OPN/
CLO
RADIO
OPEN
CLO SE
PUSH
STO P
PUSH
CLO SE
PHOT O
OPEN
PHOT O
LD1 8
LD1 0
LD1 1
LD1 2
LD1 5
LD1 4
LD1 6
LD1 7
LD1 3
OPE N
CLOS E
STOP
OPE N
CLOSE
FORCE
ADJUSTM ENT
AUTO
RECLOSE
TIME R
OFF
MAX
MID
LIMIT
REV
LO OP
OPN
EDGE
CLO
EDGE
RH OPN
LH CLO
LIMIT
RH CLO
LH OPN
LIMIT
MOTO R
OPEN
MOTO R
CLO SE
SHADOW
LO OP
LD19
LD2
LD3
LD4
LD5
LD6
LD8
LD9
LD7
1 2 3 4 5
POW ER
LD1
P3
P4
TB 1
TB 2
U1
U2
U4
MASTER OPERATOR
CONTROL BOARD
SLAVE OPERATOR
CONTROL BOARD
MASTER/SLAVE INSTALLATION
NOTE:
A single unit is considered a Master.
1. Place dipswitch #5 on the
MASTER
operator’s control
board in the
“OFF”
position.
2. Place dipswitch #5 on the
SLAVE
operator’s control
board in the
“ON”
position.
3. Connect a wire from the
“MST OPN”
terminal on the
Master
operators control board, to the
“OPN”
terminal
on the
Slave
operators control board.
4. Connect a second wire from the
“MST CLO”
terminal
on the
Master
operators control board, to the
“CLO”
terminal on the slave operators control board.
5. Connect a third wire from any
“COM”
terminal on the
Master
operators control board, to any
“COM”
terminal on the
Slave
operators control board.
NOTE:
In a Master/Slave installation, one unit must be
converted to
LEFT HAND
operation.
28
CO
M
CO
M
CO
M
24
V
AC
24
V
AC
AL
T
RD
O
OP
N
CR
O
FR
E
OP
N
CL
O
ST
O
CO
M
CO
M
CO
M
OP
N
PHO
CL
O
PHO
SHW
RE
V
OP
N
ED
G
CL
O
EDG
MS
T
OP
N
MS
T
CL
O
CO
M
CO
M
CO
M
OPEN
PUSH
FREE
EXT
ALT
RADIO
OPN/
CLO
RADIO
OPEN
CLOSE
PUSH
STOP
PUSH
CLOSE
PHOTO
OPEN
PHOTO
LD18
LD10
LD11
LD12
LD15
LD14
LD16
LD17
LD13
OPEN
CLOSE
STOP
OPE N
CLOSE
FORCE
ADJUS TMENT
AUT O
RECLOS E
TIMER
OFF
MAX
MID
LIMIT
REV
LOOP
OPN
EDGE
CLO
EDGE
RH OPN
LH CLO
LIMIT
RH CLO
LH OPN
LIMIT
MOTOR
OPEN
MOTOR
CLOSE
SHADOW
LOOP
LD19
LD2
LD3
LD4
LD5
LD6
LD8
LD9
LD7
1 2 3 4 5
POWER
LD1
P3
P4
TB1
TB2
U1
U2
U4
CO
M
CO
M
CO
M
24
V
AC
24
V
AC
AL
T
RD
O
OP
N
CR
O
FR
E
OP
N
CL
O
ST
O
CO
M
CO
M
CO
M
OP
N
PHO
CL
O
PHO
SHW
RE
V
OP
N
ED
G
CL
O
EDG
MS
T
OP
N
MS
T
CL
O
CO
M
CO
M
CO
M
OPEN
PUSH
FREE
EXT
ALT
RADIO
OPN/
CLO
RADIO
OPEN
CLOSE
PUSH
STOP
PUSH
CLOSE
PHOTO
OPEN
PHOTO
LD18
LD10
LD11
LD12
LD15
LD14
LD16
LD17
LD13
OPEN
CLOSE
STOP
OPE N
CLOSE
FORCE
ADJUS TMENT
AUT O
RECLOSE
TIMER
OFF
MAX
MID
LIMIT
REV
LOOP
OPN
EDGE
CLO
EDGE
RH OPN
LH CLO
LIMIT
RH CLO
LH OPN
LIMIT
MOTOR
OPEN
MOTOR
CLOSE
SHADOW
LOOP
LD19
LD2
LD3
LD4
LD5
LD6
LD8
LD9
LD7
1 2 3 4 5
POWER
LD1
P3
P4
TB1
TB2
U1
U2
U4
MASTER
SLAVE
OPN PH
O
CL
O
PH
O
SH
W
RE
V
OP
N
ED
G
CL
O
ED
G
MS
T
OPN
MS
T
CL
O
CO
M
CO
M
CO
M
AUTO
RECLOSE
TIMER
OFF MAX
MOTOR
OPEN
MOTOR
CLOSE
SHADOW
LOOP
LD9
LD7
1 2 3 4 5
CO
M
CO
M
CO
M
24
V
AC
24
V
AC
AL
T
RD
O
OPN
CR
O
FR
E
OP
N
CL
O
ST
O
CO
M
STOP
PUSH
CLOSE
PHOTO
OPEN
PHOTO
LD16
LD17
LD13
OPEN
CLOSE
FORCE
ADJUSTMENT
TB1
U4
MASTER OPERATOR
CONTROL BOARD
SLAVE OPERATOR
CONTROL BOARD