V1.01
87
enabled.
Restarting after over-discharge protection can take up to several hours.
INSTALLATION
General
Check the battery for external damage before installing it.
If there is any visible damage, do not install or use the battery and immediately contact
contact your supplier.
The battery must always be used with an appropriate external fuse in the load circuit.
The battery can be installed upright, portrait or landscape.
The battery must be installed firmly and securely in the vehicle or system; very possible in campers
often use the existing confirmation.
The terminals and terminals must be covered after installation to protect against
short circuit, existing round terminal blocks can be used.
Never connect batteries with consumers switched on to avoid sparking.
-Do not expose the battery to direct sunlight and install the battery indoors, away from
heat sources.
Charge before use, the battery is only charged to 40-60% during transport.
Series
–
parallel connection
PowerBoozt LiFePO4 batteries can be connected in series and/or parallel, note:
Before installation, check that the batteries have a voltage difference of max. 50mV; if not this
if so, charge them both separately to 100% and then equalize them by separating them
to discharge
With series connection (max. 4 batteries) the voltage increases, but the capacity does not.
When connected in parallel (max. 4 batteries), the capacity increases, the voltage does not change. The
currents for both charging and discharging increase accordingly.
A circuit in which the batteries are connected in both series and parallel is theoretically possible,
but is not recommended.
In case of series or parallel connection, the positive and negative cables for the mutual
connections have the same cable length. The cross-sections must also be equal.
Consumers and chargers must be connected "diagonally" in case of parallel connection,
i.e. positive of the first battery, negative of the last or vice versa.
Summary of Contents for LfeLi-48100TB
Page 10: ...V1 01 10...
Page 11: ...V1 01 11 PB UPS 2K24 PB UPS 3K24 PB UPS 5K48...
Page 12: ...V1 01 12...
Page 62: ...V1 01 62...
Page 63: ...V1 01 63 PB SC12 170...
Page 64: ...V1 01 64...
Page 81: ...V1 01 81 PB Li 12 100D...
Page 82: ...V1 01 82...
Page 100: ...V1 01 100...
Page 101: ...V1 01 101 LfeLi 48100TB...
Page 102: ...V1 01 102...
Page 105: ...V1 01 105 Product structure LFeLi frontpanel...
Page 137: ...V1 01 137 APPENDIX...
Page 138: ...V1 01 138...
Page 139: ...V1 01 139 COMPOSITION AND SETTINGS SYSTEMS PB UPS 2 2 24...
Page 141: ...V1 01 141 PB LSC 1 PB SC12 170 PB UPS 2K24...
Page 142: ...V1 01 142...
Page 143: ...V1 01 143 PB UPS 3 5 24...
Page 145: ...V1 01 145 PB LSC 1 dimensions in mm PB SC12 170 dimensions in mm...
Page 146: ...V1 01 146 PB UPS 3K24 dimensions in mm...
Page 147: ...V1 01 147 PB UPS 5 5 48...
Page 149: ...V1 01 149 PB LSC 1 dimensions in mm PB SC12 170 dimensions in mm...
Page 150: ...V1 01 150 PB UPS 5K48 dimensions in mm...
Page 151: ...V1 01 151 PB UPS 10 10 48...
Page 153: ...V1 01 153...
Page 154: ...V1 01 154 PB LSC 2 dimensions in mm B SC12 170 dimensions in mm...
Page 155: ...V1 01 155 PB UPS 5K48 dimensions in mm...
Page 156: ...V1 01 156 PB UPS 15 15 48...
Page 158: ...V1 01 158...
Page 159: ...V1 01 159 PB LSC 2 dimensions in mm B SC12 170 dimensions in mm...
Page 160: ...V1 01 160 PB UPS 5K48 dimensions in mm...
Page 161: ...V1 01 161 PB UPS 2 2 24 Li...
Page 163: ...V1 01 163 PB LSC 1 PB Li 12 100D...
Page 164: ...V1 01 164 PB UPS 2K24...
Page 165: ...V1 01 165 PB UPS 3 5 24 Li...
Page 167: ...V1 01 167 PB LSC 1 PB Li 12 100D...
Page 168: ...V1 01 168 PB UPS 2K24...
Page 169: ...V1 01 169 PB UPS 5 5 48 Li...
Page 171: ...V1 01 171 LfeLi48100T dimensions in mm PB LSC Li dimensions in mm...
Page 172: ...V1 01 172 PB UPS 5K48 dimensions in mm...
Page 173: ...V1 01 173 PB UPS 10 10 48 Li...
Page 175: ...V1 01 175 LfeLi48100T dimensions in mm PB LSC Li dimensions in mm...
Page 176: ...V1 01 176 PB UPS 5K48 dimensions in mm...
Page 177: ...V1 01 177 PB UPS 15 15 48 Li...
Page 179: ...V1 01 179 LfeLi48100T dimensions in mm PB LSC Li dimensions in mm...
Page 180: ...V1 01 180 PB UPS 5K48 dimensions in mm...
Page 183: ...V1 01 183 ANL MEGA...
Page 190: ...V1 01 190...
Page 191: ...V1 01 191...
Page 192: ...V1 01 192...