With the discharge process, the specific gravity of electrolyte changes greatly (it is impossible to
measure, only calculate the results), so the open circuit voltage is measured. The approximate
residual capacity can be calculated
.
The figure below shows the relationship between the open clamp voltage and the state of charge (state
of charge
–
SOC
).
Recharge
Generally speaking, lead sulfate will be produced in the battery negative plate, this is called "sulfate"
after they were stored for a long time.Because lead sulfate is an insulator, it will influence the
performance of the charge. therefore it is recommended that the battery is stored in a dry, cool the
environment
.
Temperature Time before rechargment
-1- <20°C
9 months
-2- 20°C
̴
30°C 6 months
-3- >30°C
̴
40°C
3 months
Recharge management:
-1- Constant voltage (2,23
̴
2,27)V/Cell, current limit 0.25C10 (2
̴
3) days.
-2- Constant voltage (2,30
̴
2,40)V/Cell, current limit 0,25C10 (10
̴
16) hours.
-3- 0,1C1 constant current charge for 8h or 0,05C10 constant current charge.
Summary of Contents for LfeLi-48100TB
Page 10: ...V1 01 10...
Page 11: ...V1 01 11 PB UPS 2K24 PB UPS 3K24 PB UPS 5K48...
Page 12: ...V1 01 12...
Page 62: ...V1 01 62...
Page 63: ...V1 01 63 PB SC12 170...
Page 64: ...V1 01 64...
Page 81: ...V1 01 81 PB Li 12 100D...
Page 82: ...V1 01 82...
Page 100: ...V1 01 100...
Page 101: ...V1 01 101 LfeLi 48100TB...
Page 102: ...V1 01 102...
Page 105: ...V1 01 105 Product structure LFeLi frontpanel...
Page 137: ...V1 01 137 APPENDIX...
Page 138: ...V1 01 138...
Page 139: ...V1 01 139 COMPOSITION AND SETTINGS SYSTEMS PB UPS 2 2 24...
Page 141: ...V1 01 141 PB LSC 1 PB SC12 170 PB UPS 2K24...
Page 142: ...V1 01 142...
Page 143: ...V1 01 143 PB UPS 3 5 24...
Page 145: ...V1 01 145 PB LSC 1 dimensions in mm PB SC12 170 dimensions in mm...
Page 146: ...V1 01 146 PB UPS 3K24 dimensions in mm...
Page 147: ...V1 01 147 PB UPS 5 5 48...
Page 149: ...V1 01 149 PB LSC 1 dimensions in mm PB SC12 170 dimensions in mm...
Page 150: ...V1 01 150 PB UPS 5K48 dimensions in mm...
Page 151: ...V1 01 151 PB UPS 10 10 48...
Page 153: ...V1 01 153...
Page 154: ...V1 01 154 PB LSC 2 dimensions in mm B SC12 170 dimensions in mm...
Page 155: ...V1 01 155 PB UPS 5K48 dimensions in mm...
Page 156: ...V1 01 156 PB UPS 15 15 48...
Page 158: ...V1 01 158...
Page 159: ...V1 01 159 PB LSC 2 dimensions in mm B SC12 170 dimensions in mm...
Page 160: ...V1 01 160 PB UPS 5K48 dimensions in mm...
Page 161: ...V1 01 161 PB UPS 2 2 24 Li...
Page 163: ...V1 01 163 PB LSC 1 PB Li 12 100D...
Page 164: ...V1 01 164 PB UPS 2K24...
Page 165: ...V1 01 165 PB UPS 3 5 24 Li...
Page 167: ...V1 01 167 PB LSC 1 PB Li 12 100D...
Page 168: ...V1 01 168 PB UPS 2K24...
Page 169: ...V1 01 169 PB UPS 5 5 48 Li...
Page 171: ...V1 01 171 LfeLi48100T dimensions in mm PB LSC Li dimensions in mm...
Page 172: ...V1 01 172 PB UPS 5K48 dimensions in mm...
Page 173: ...V1 01 173 PB UPS 10 10 48 Li...
Page 175: ...V1 01 175 LfeLi48100T dimensions in mm PB LSC Li dimensions in mm...
Page 176: ...V1 01 176 PB UPS 5K48 dimensions in mm...
Page 177: ...V1 01 177 PB UPS 15 15 48 Li...
Page 179: ...V1 01 179 LfeLi48100T dimensions in mm PB LSC Li dimensions in mm...
Page 180: ...V1 01 180 PB UPS 5K48 dimensions in mm...
Page 183: ...V1 01 183 ANL MEGA...
Page 190: ...V1 01 190...
Page 191: ...V1 01 191...
Page 192: ...V1 01 192...