6-106
PFC-6075 • 5403593 • Rev C • 2/13
Municipal Box Connection
When the PSN-1000/PSN-1000(e) is programmed as a municipal box connection, the circuit is power limited and supervised for
open and short circuit conditions. It also provides a local energy connection. Please refer to the figure shown below for a wiring
example.
Configuration Characteristics
NAC1-NAC6's trip current is 3 amps.
y
y
Maximum voltage rating is 24 vDC.
y
y
Notes:
The panel has ground fault detection on municipal box connection circuits.
1.
The impedance to ground for ground fault detection is 0 ohms.
2.
PSN-1000 Configured as Municipal Box
Figure 147.
-
I1 + - NAC 1 + - NAC 5 + - NAC 3 +
-
+ A B
-
I2 + - NAC 2 + - NAC 4 + - NAC 6 +
-
+ A B
P-LINK
Notes:
The EOL device shall be installed in the same electrical
enclosure as the Municipal Box.
Municipal
Box
+
-
End of line device
5.1k ohm 1/2W
Part #3005012
Relay Outputs
The board has two (2) relay outputs: a dedicated
Trouble relay
and a
Low AC relay
. The dedicated
Trouble relay
is a failsafe
trouble relay that changes position anytime a trouble condition occurs.
The relays have a contact rating is 24vDC / 3.0A, 125vAC / 3A, and a Power Factor of 1.0. These outputs are
non-power limited
and
are not supervised.
Note:
If the power supply is power-limited, then the outputs are power limited.
PSN-1000's Relay Outputs
Figure 148.
LOW AC
NC COM NO
TROUBLE
NC COM NO
DWG #602-31
DWG #602-32