15
MA-Di
COMPRESSED AIR AT ITS BEST
5
INSTALLATION
5.1
Identifying the installation position
For the installation position, it is necessary to observe the specified
technical data (
Section 4.1 | p. 12).
At site the following points must be observed:
•
Fluid at the installation position must be non-condensing
, the
measurement location can, for this reason, only be arranged behind
a suitable compressed air drier that provides a suitable pressure dew
point. Otherwise, the specified measuring accuracy is not ensured.
•
Ambient temperature of max + 60 °C
(possible heat radiation must be
taken into account).
•
Consider the required measuring distance
(
5.4 | p. 17).
•
Observe the inflow direction during the installation
(
5.5 | p. 18).
•
Easily accessible and low in vibrations
.
•
Installation-free space of at least 600 mm
is required for dismantling
the sensor.
5.2
Linear dimension of the measuringSYSTEM
5 Installation
Strömungsrichtung
H
O
d
G
L
H1
E
SW
O
D
flow direction