AK355 System Installation and User's Guide
Positron Access Solutions
101
180-0037-002 R01
DS3 CO unit Parameters and Values table
Parameters
Values
DS3 Circuit ID
Allows input of description
of the DS3 circuit up to 48 characters.
DS3 Line Format
C-Bit Parity
Asynchronous M13
CO unit DS3 Line
Build Out
0..225 ft
226..450 ft
Output Mode (Alarm
Mode)
Normal - Idle, Alarm
Indication Signal (AIS)
Payload Type
Channelized DS3 (TDM)
ATM*
Scrambled ATM*
Clear Channel
Loopback Timeout
0, 20, 60, 3600 (24 hours)
minutes
FEAC Pass Through
YES
- DS3 FEAC loopback
messages from the network
are reacted upon by the CO.
NO
- DS3 FEAC loopback
messages from the network
are ignored.
State
UP
- CO DS3 port is in service.
Down
- CO DS3 port is out of
service.
DS3 RT unit Parameters and Values table
Parameters
Values
DS3 Circuit ID
Allows input of description of the DS3
circuit up to 48 characters.
RT Unit DS3 Line Build
Out
0..225 ft
226..450 ft
State
UP - RT DS3 port is in service
Down - RT DS3 port is out of service
Summary of Contents for AK355
Page 1: ...AK355 System Installation and User s Guide...
Page 25: ...AK355 System Installation and User s Guide Positron Access Solutions 25 180 0037 002 R01...
Page 26: ...AK355 System Installation and User s Guide Positron Access Solutions 26 180 0037 002 R01...
Page 32: ...AK355 System Installation and User s Guide Positron Access Solutions 32 180 0037 002 R01...
Page 51: ...AK355 System Installation and User s Guide Positron Access Solutions 51 180 0037 002 R01...
Page 53: ...AK355 System Installation and User s Guide Positron Access Solutions 53 180 0037 002 R01...
Page 95: ...AK355 System Installation and User s Guide Positron Access Solutions 95 180 0037 002 R01...
Page 96: ...AK355 System Installation and User s Guide Positron Access Solutions 96 180 0037 002 R01...
Page 109: ...AK355 System Installation and User s Guide Positron Access Solutions 109 180 0037 002 R01...
Page 120: ...AK355 System Installation and User s Guide Positron Access Solutions 120 180 0037 002 R01...