AK355 System Installation and User's Guide
Positron Access Solutions
103
180-0037-002 R01
The following is the DS1 provisioning dialog box:
See the following table for parameters and values:
DS1 Provisioning Parameters and Values
Parameter
Values
Circuit ID
Circuit ID of DS1 up to 48
characters
Priority
0 [Low] through 7 [High]
When system needs to
downshift
the MSPAN rate during
adverse
conditions (e.g. a pair failed),
the
priority parameter
determines the
order of DS1's dropped.
State
Down
- DS1 tributary is not
transported.
UP
- DS1 tributary is
transported.