AK355 System Installation and User's Guide
Positron Access Solutions
113
180-0037-002 R01
See the following table for Parameters and Values:
MSPAN General Parameters
Values
State
Sets the MSPAN State:
Up - MSPAN is in service
Down - MSPAN is out of service
Circuit ID
User configurable string of up to 48 characters
Mode
Sets the MSPAN Mode:
Symmetric
Asymmetric
MSPAN Rate (kbps)
Sets the MSPAN Rate in Symmetric Mode
Rate Upstream
Sets the Upstream MSPAN Rate in Asymmetric Mode
Rate Downstream
Sets the Downstream MSPAN Rate in Asymmetric Mode
Line Powering
Sets Line Powering to: Off, -135v, or -185v
SNR Margin
Sets the SNR Margin: 0 to 18dB
Margin Threshold
Sets the SNR Margin Threshold. If the SNR Margin falls below this
threshold, an Alarm will be generated
Reserve Pairs
Sets the number of Reserve Pairs
PSD Mask
Sets the PSD Mask:
Auto - Select the PSD Mask automatically
Select - M0, M1, M2, M3, M4 or M5
2.2 Mhz
If the 2.2 Mhz feature is enabled:
Select - Auto, or No
Summary of Contents for AK355
Page 1: ...AK355 System Installation and User s Guide...
Page 25: ...AK355 System Installation and User s Guide Positron Access Solutions 25 180 0037 002 R01...
Page 26: ...AK355 System Installation and User s Guide Positron Access Solutions 26 180 0037 002 R01...
Page 32: ...AK355 System Installation and User s Guide Positron Access Solutions 32 180 0037 002 R01...
Page 51: ...AK355 System Installation and User s Guide Positron Access Solutions 51 180 0037 002 R01...
Page 53: ...AK355 System Installation and User s Guide Positron Access Solutions 53 180 0037 002 R01...
Page 95: ...AK355 System Installation and User s Guide Positron Access Solutions 95 180 0037 002 R01...
Page 96: ...AK355 System Installation and User s Guide Positron Access Solutions 96 180 0037 002 R01...
Page 109: ...AK355 System Installation and User s Guide Positron Access Solutions 109 180 0037 002 R01...
Page 120: ...AK355 System Installation and User s Guide Positron Access Solutions 120 180 0037 002 R01...