AK355 System Installation and User's Guide
Positron Access Solutions
81
180-0037-002 R01
2.3.10.2 DELT
Dual Ended Loop Test (DELT) provides diagnostics for each pair. Follow this
procedure to run DELT:
1 DELT is service effecting. The remote unit must be
connected
2 Click on Start Testing button to run the DELT test. The Status of the
DELT test is indicated.
to run the
test.
3 The results can be exported to an Excel csv file by clicking on the Export
Test Result button.
The results of the DELT test are indicated below:
For each pair's tip and ring, the current in milliamps is indicated on itself an
between that pair and every other pair being used in the AK355 System. The
screen shot above shows a normal result. There should be current flowing
between Pair1 and T1and R1, between Pair 2 and T2 and R2. The current flow
Summary of Contents for AK355
Page 1: ...AK355 System Installation and User s Guide...
Page 25: ...AK355 System Installation and User s Guide Positron Access Solutions 25 180 0037 002 R01...
Page 26: ...AK355 System Installation and User s Guide Positron Access Solutions 26 180 0037 002 R01...
Page 32: ...AK355 System Installation and User s Guide Positron Access Solutions 32 180 0037 002 R01...
Page 51: ...AK355 System Installation and User s Guide Positron Access Solutions 51 180 0037 002 R01...
Page 53: ...AK355 System Installation and User s Guide Positron Access Solutions 53 180 0037 002 R01...
Page 95: ...AK355 System Installation and User s Guide Positron Access Solutions 95 180 0037 002 R01...
Page 96: ...AK355 System Installation and User s Guide Positron Access Solutions 96 180 0037 002 R01...
Page 109: ...AK355 System Installation and User s Guide Positron Access Solutions 109 180 0037 002 R01...
Page 120: ...AK355 System Installation and User s Guide Positron Access Solutions 120 180 0037 002 R01...