- 102 -
7 seconds
Y7
8 seconds
Y8
9 seconds
Y9
Read time * 10
YL
Indefinitely
YM
END
5.3. Redundancy
This is the number of times that a label must be correctly decoded before it is
transmitted. Selecting a higher redundancy count makes reading slower, but it reduces
the probability of reading errors, especially when labels of poor definition are used.
SET
Read 1 time, redundancy = 0
X0
Read 2 times,
redundancy
= 1
X1
Read 3 times, redundancy = 2
X2
Read 4 times, redundancy = 3
X3
END
5.4. Positive and negative bar codes
Usually bar codes are printed black on white, but sometimes white on black. These
labels are called positive and negative respectively. In case the 'negative bar codes'
option has been selected, positive labels may not be decoded anymore or with
difficulty. This also applies to menu labels. To enable the reader to read positive
labels again, a number of negative menu labels have been included.