6.2.3 Configuring the Analog inputs.
Set-up line
Functionality
Input 1
Programming of Analog Input No.1:
Inactive
(no programmed action)
Current
: if a sensor is connected which generates a signal of 0/4-20 mA
Voltage
: if a sensor is connected which operates within a 0-10 V range
I1: Signal min
For a
Current
input: can be set to a value between 0 and 20 mA
For a
Voltage
input: can be set to a value between 0 and 10V
I1: Signal max
For a
Current
input: can be set to a value between the minimum value set
up in the "Signal min" line and 20 mA.
For a
Voltage
input: can be set to a value between the minimum value set
up in the "Signal min" line and 10 V.
I1: Average
Used to set the number of measurements, from 1 (instantaneous value) to
50, from which the moving average is calculated.
I1: Refresh rate
This line lets the operator select the interval between each measurement.
The possible values are:1 to 60 seconds.
I1: Error reporting
Inactive
(no error reporting)
Out-of-range alert
: if the measurement falls outside of the range
programmed by the Signal min and Signal max lines, information is sent to
the relay output if the programming is set to "Alarm mode" (refer to section
6.2.6).
I1: Source signal 1
units
----------- : units not selected
mH
2
O
: water height measurement sensor
mbar:
pressure sensor
bar
: pressure sensor
I1: Source signal 1 min
This line lets the operator set the minimum value to between -9999.99 and
9999.9
I1: Source signal 1
max
This line lets the operator set the maximum value to between the minimum
value set on the "Source signal 1 min" line and 9999.9.
I1: Source signal 1
display
This line lets the operator arrange the information displayed on the home
screen (refer to Table 2 for parameter display details)
Not displayed
Sens 1. Prim. Meas.
: the measurement shall be displayed in the space
allocated to the primary parameter for sensor 1 (item 3 on the home screen)
Sens 1. Sec. Meas.
: item 9 on the home screen.