Summary of Contents for SK 5012

Page 1: ...SK 5012 GEBRAUCHSANLEITUNG INSTRUCTION MANUAL NOTICE D EMPLOI ISTRUZIONI PER L USO INSTRUCCIONES PARA EL USO GEBRUIKSAANWIJZING BRUKSANVISNING SK5012 book Seite 1 Montag 23 Juli 2001 3 43 15 ...

Page 2: ...SK5012 book Seite 2 Montag 23 Juli 2001 3 43 15 ...

Page 3: ...SK 5012 3 English Delivery includes SK 5012 Antenna 2 Batteries Attachment clip Screwdriver SK5012 book Seite 3 Montag 23 Juli 2001 3 43 15 ...

Page 4: ...D for operation battery status and peak indication 3 Antenna socket 4 Sensitivity switch 5 Channel selector switch 6 Frequency channel data plate 7 Type plate in battery compartment 8 ON OFF switch 1 2 3 4 5 6 7 8 SK5012 book Seite 4 Montag 23 Juli 2001 3 43 15 ...

Page 5: ...a century of accumulated expertise in the design and manufacture of high quality of electro acoustic equipment have made Sennheiser a world leading company in this field Due to its extremely flat design and small dimensions the SK 5012 is espe cially suitable for applications where a very unobtrusive transmitter is being required SK5012 book Seite 5 Montag 23 Juli 2001 3 43 15 ...

Page 6: ...nes State of the art PLL technology 16 switchable channels HiDyn plusTM noise reduction system Signal to noise ratio 110 dB A Voltage converter ensures constant output power until the batteries are completely discharged LED operation indicator LED lights up dimly LED low battery indicator LED blinks periodically LED peak indicator LED flashes brightly Reliable easy to use clip attachement SK5012 b...

Page 7: ...ing the two catches at the sides Insert the two batteries into the battery compartment When closing the transmitter make sure that the two catches at the sides lock into place The transmitter can also be powered by rechargeable batteries SK5012 book Seite 7 Montag 23 Juli 2001 3 43 15 ...

Page 8: ...ize alkaline manganese batteries IEC LR 03 Turning the transmitter on Set the ON OFF switch to ON The red LED lights up dimly This LED also serves as a peak indicator LED flashes brightly and low battery indicator LED blinks periodi cally SK5012 book Seite 8 Montag 23 Juli 2001 3 43 15 ...

Page 9: ...ompletely discharged When the remaining operation time is approx 30 minutes the LED starts blinking periodi cally As the batteries discharge the blinking of the LED accelera tes Note If the transmitter is powered by rechargeable batteries the LED only starts blinking shortly before the batteries are com pletely discharged SK5012 book Seite 9 Montag 23 Juli 2001 3 43 15 ...

Page 10: ...are fitted with a special Lemo plug The supply voltage for powering these micro phones is available at the transmit ter s microphone input Connect the microphone s Lemo plug to the socket at the top of the transmitter and lock the connection by screwing down the coupling ring SK5012 book Seite 10 Montag 23 Juli 2001 3 43 15 ...

Page 11: ...the channel selector switch to the desired position The assign ment of a switch position channel to a frequency is listed on the fre quency channel data plate see inside battery compartment cover SK5012 book Seite 11 Montag 23 Juli 2001 3 43 15 ...

Page 12: ...ign the transmit ter can easily be attached to your clothing e g pocket waistband belt by means of the supplied clip To avoid kinking the antenna the clip can be withdrawn from its fixing points and attached the other way round Make sure not to kink the antenna SK5012 book Seite 12 Montag 23 Juli 2001 3 43 15 ...

Page 13: ...und levels In practice the following set tings have proved their worth for adjusting the sensitivity Position 1 high frequency loud audio material with many plosives Position 2 3 loud voices vocals theater applications close miking Position 3 4 5 normal voices talkshows Position 6 soft voices SK5012 book Seite 13 Montag 23 Juli 2001 3 43 15 ...

Page 14: ...htly only during peak levels When adjusting the sensitivity hold or attach the microphone exactly where it will be positio ned during use HiDyn plusTM This transmitter is equiped with HiDyn plusTM the Sennheiser noise reduc tion system that reduces RF interference Together with a receiver which is also equipped with HiDyn plusTM e g EM 1046 an RF link of excellent operational reliability and high ...

Page 15: ...manufacturers may cause damage to the unit and will invalidate the warranty The following lavalier clip on microphones are available MKE 2 4 MKE 102 4 omnidirectional pick up pattern MKE 40 4 MKE 104 4 cardioid pick up pattern Please order from your local Sennheiser dealer SK5012 book Seite 15 Montag 23 Juli 2001 3 43 15 ...

Page 16: ...eceiver set to the same frequency Receiving antenna within the transmitter s range Transmitter shielded by metal constructions or metallic clothing or antenna in direct contact with the skin If the problem resists please contact your specialist dealer for assistance Attention Never open the device SK5012 book Seite 16 Montag 23 Juli 2001 3 43 15 ...

Page 17: ...z Compander system Sennheiser HiDyn plusTM Input sensitivity 49 mVeff 24dBu for nominal deviation 1 kHz AF switchable in 5 steps of 8 dB max input voltage 1 55 Vrms AF frequency response 60 Hz 20 kHz Signal to noise ratio 110 dB A rms THD 0 3 at nominal deviation 1 kHz Connections AF 3 pin Lemo RF special co ax Lemo Weight with batteries approx 230 g Operating time with primary cells with alkaline...

Page 18: ...SK 5012 18 English SK5012 book Seite 18 Montag 23 Juli 2001 3 43 15 ...

Page 19: ... KG declare that this device is in com pliance with the applicable CE standards and regulations Before putting this device into operation please observe the respective country specific regulations Certification Sennheiser electronic GmbH Co KG déclarons que cet appareil est en conformité avec les normes CE Avant d utiliser l appareil vieullez observer les dispositions légales en vigueur dans votre...

Page 20: ... electronic GmbH Co KG declaramos que este aparato cumple las normas y directrices de la CE aplicables Antes de la puesta en funcionamento deberán observarse los respectivos reglamientos nacionales Vergunning Sennheiser electronic GmbH Co KG verklaren dat dit toestel voldoet de toepasselijke CE normen en voorschriften Voor inbedrijftstelling dient u de afzonderlijke landspecifieke voorschriften in...

Page 21: ...SK5012 book Seite 21 Montag 23 Juli 2001 3 43 15 ...

Page 22: ...ervado el derecho a introducir modificationes Wijzigingen voorbehouden Med förbehåll för ändringar Sennheiser electronic GmbH Co KG Telefon 49 0 5130 600 0 D 30900 Wedemark Telefax 49 0 5130 600 300 www sennheiser com Printed in Germany Publ 07 01 82568 A01 SK5012 book Seite 22 Montag 23 Juli 2001 3 43 15 ...