Polaris DP-20 User Manual Download Page 1

 

 
 
 
 
 
 
 

POLARIS DP-20

WEB GUIDE CONTROLLER

 

User Manual 

 

 

 

              1A

      AUTOMATIC 

×  -ãããããÜÜÜÜÜ+ 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

06-05-2007 

© 2007 Fife Corporation.  All rights reserved.

 

Figure Sheet 1-862-D 

Summary of Contents for DP-20

Page 1: ...POLARIS DP 20 WEB GUIDE CONTROLLER User Manual 1A AUTOMATIC ãããããÜÜÜÜÜ 06 05 2007 2007 Fife Corporation All rights reserved Figure Sheet 1 862 D ...

Page 2: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...

Page 3: ... in this User Manual is subject to change without notice We have compiled this User Manual with the greatest possible care and attention however the possibility of error can not be completely excluded Fife Corporation accepts no legal liability for incorrect information given and the consequences arising there from Copyright 2007 Fife Corporation All rights reserved 06 05 2007 DP 20 WEB GUIDE CONT...

Page 4: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...

Page 5: ...t 5 2 6 SYSTEM SETUP MENUS AVAILABLE FROM MANUAL MODE 6 1 Basic Menus 6 1 3X 1 1 System Gain 6 1 3X 1 2 System Guide Point 6 1 3X 1 3 Guide Polarity 6 2 3X 1 4 Calibration Edge Sensors 6 3 3X 1 4 Calibration Line Sensor Center of Line Guiding 6 4 3X 1 4 Calibration Line Sensor Edge of Line Guiding 6 5 3X 1 4 Calibration Servo Center Sensor 6 7 3X 1 5 Auto Setup 6 8 3X 1 6 Servo Center Gain 6 9 3X ...

Page 6: ...I O Enable Disable 6 27 3X 3 8 1 Test Signals Sensor Current 6 27 3X 3 8 2 Test Signals Toggle Outputs 6 28 3X 3 8 3 Test Signals Guide Test Mode 6 29 Language Menu 6 31 3X 4 1 Select Language 6 31 Custom Menus 6 32 3X 5 1 ASC Control 6 32 3X 5 2 Set ASC Limits 6 33 3X 5 3 Set ASC Source 6 34 7 PARALLEL MATRIX 7 1 Parallel Input Matrix 7 1 Parallel Output Matrix 7 1 8 SYSTEM NOTES 8 1 9 TROUBLESHO...

Page 7: ...ble to operate in a variety of sensor modes such as Fixed Sensor Center Guide or Edge Guiding from either edge Edge of Line or Center of Line Guiding is also supported The DP 20 can be either panel mounted or wall mounted with optional mounting bracket The DP 20 Web Guide Controller is designed to control one motor up to and including a 1 3 Amp motor provided by Fife Corporation 06 05 2007 DP 20 W...

Page 8: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...

Page 9: ...he sensor s to be used for monitoring the web position when the system is in Automatic mode Sensor selection is allowed in Manual and Servo Center modes only SETUP This key is used to enter the Setup Menus for configuring and adjusting the guiding system ARROW This key is used to jog the guide The direction of guide movement is configurable This key is also used during setups to scroll through the...

Page 10: ...e symbol of the current sensor selection is displayed in this line LINE 1 A command present on the Digital I O is indicated by an asterisk in this line LINE 1 An External Lock command present on the Digitital I O is indicated by an asterisk surrounded by parentheses in this line LINE 1 An unrecognized command present on the parallel port is indicated by a question mark in this line LINE 1 While in...

Page 11: ... Servo Center mode this line contains the Servo Center sensor symbol ƒ and also a bargraph indicating the signal level of the Servo Center sensor LINE 3 While in the Setup Menus this line indicates the title of the current menu selection LINE 4 While at the Operator Level this line displays the Guide Point value if the value is not zero LINE 4 While at the Operator Level in Automatic or Servo Cent...

Page 12: ... it is possible to modify the value it will be flashing LINE 4 While at the Operator Level in Automatic mode Servo Center mode or Manual mode if no motor is detected on the Drive connector X1 NO MOTOR is displayed on this line 3A 2 2 SETUP MAN GUIDE POINT ÜÜÜÜåÜÜ 20 0 3A MANUAL ãããããáÜÜÜÜ NO MOTOR 06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D ...

Page 13: ...nd return to the Operator Level While in Automatic Mode or Servo Center Mode the Gain and Guide Point changes are stored While in Manual Mode all changes that were not previously stored are discarded 6 While in the Setup Menus if FAILED is displayed the MANUAL key must be pressed to exit the Setup Menus and return to the Operator Level 7 If a menu is password protected the letter X will be indicat...

Page 14: ...d Set Output A Delay Set Output B Delay Loss of Null Output Range Digital I O X3 Test Signals Exit Menus LANGUAGE MENU 3X 4 1 Select Language CUSTOM MENUS 3X 5 1 3X 5 2 3X 5 3 3X 5 4 ASC Control Set ASC Limits Set ASC Source Exit Menus MEASUREMENT SUBMENUS 1X 3 1 2X 3 1 3X 1 8 1 1X 3 2 2X 3 2 3X 1 8 2 1X 3 3 2X 3 3 3X 1 8 3 1X 3 4 2X 3 4 3X 1 8 4 1X 3 5 2X 3 5 3X 1 8 5 1X 3 6 2X 3 6 3X 1 8 6 1X 3 ...

Page 15: ...the ARROW keys simultaneously to reset the System Gain to 10 0 as indicated on line 4 5 Press the ENTER key to store the change or press the MANUAL key to abort the change The system will exit the setup menus and return to the Operator Level Ø 1C 1 SETUP AUTO GAIN ãÜÜÜÜÜÜÜÜÜ 10 0 Ø 1C 1 1 SETUP AUTO GAIN ãÜÜÜÜÜÜÜÜÜ 10 0 Ø 1C 1 1 SETUP AUTO GAIN ããÜÜÜÜÜÜÜÜ 20 0 Ø 1C 1 1 SETUP AUTO GAIN ãÜÜÜÜÜÜÜÜÜ 1...

Page 16: ... keys simultaneously to reset the System Guide Point to the center of the available range as indicated on line 4 6 Press the ENTER key to store the change or press the MANUAL key to abort the change The system will exit the setup menus and return to the Operator Level The Guide Point value GP will be displayed on Line 4 if the value is not 0 Ø 1C 2 1 SETUP AUTO GUIDE POINT ÜÜÜåÜÜÜ 0 0 Ø 1C 2 1 SET...

Page 17: ... is the TACHOMETER The tachometer signal is displayed on Line 4 7 Use the ARROW keys to scroll to the desired Measurement menu Next in the list is the MOTOR TYPE The motor type is displayed on Line 4 8 Use the ARROW keys to scroll to the desired Measurement menu Next in the list is the DIGITAL INPUTS The status of the inputs is displayed on Line 4 The order in which the inputs are displayed is 5 4...

Page 18: ...keys to scroll until EXIT MENUS is displayed on line 3 Pressing the ENTER key while this screen is displayed will exit the Measurement Menus and return to the Operator Level 12 Otherwise press the MANUAL key to exit the Measurement Menus and return to the Operator Level Ø 1C 3 8 MEASUREMENT SERIAL NUMBER SN 10000 Ø 1C 3 9 MEASUREMENT EXIT MENUS 1C AUTOMATIC Ø ãããããÜÜÜÜÜ 06 05 2007 DP 20 WEB GUIDE ...

Page 19: ...e 4 5 Press the ENTER key to store the change or press the MANUAL key to abort the change The system will exit the setup menus and return to the Operator Level 2A 1 SETUP SC ƒ GAIN ãÜÜÜÜÜÜÜÜÜ 5 0 2A 1 1 SETUP SC ƒ GAIN ãÜÜÜÜÜÜÜÜÜ 5 0 2A 1 1 SETUP SC ƒ GAIN ããÜÜÜÜÜÜÜÜ 15 0 2A 1 1 SETUP SC ƒ GAIN ãÜÜÜÜÜÜÜÜÜ 5 0 2A SERVO CENTER ƒ ãããããÜÜÜÜÜ 2X 2 Servo Center Guide Point 1 Press the SETUP key to enter...

Page 20: ...CD Panel 2 Use the ARROW keys to scroll until MEASUREMENT is displayed on line 3 3 Press the ENTER key to view the Measurement menus The level of the guiding signal from the Left Edge Sensor Line Center if a line sensor is being used is displayed on Line 4 This signal has been scaled by values which were determined during the Sensor Calibration procedure 4 Use the ARROW keys to scroll to the desir...

Page 21: ...xt in the list is the FIRMWARE VERSION The version number of the firmware is displayed on Line 4 10 Use the ARROW keys to scroll to the desired Measurement menu Next in the list is the SERIAL NUMBER The serial number of the DP 20 is displayed on Line 4 11 If desired use the ARROW keys to scroll until EXIT MENUS is displayed no line 3 Pressing the ENTER key while this screen is displayed will exit ...

Page 22: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...

Page 23: ... If desired press both of the ARROW keys simultaneously to reset the System Gain to 10 0 as indicated on line 4 6 Press the ENTER key to store the change or press the MANUAL key to abort the change The system will exit the setup menus and return to the Operator Level Ø 3C 1 SETUP MAN SELECT MENU BASIC Ø 3C 1 1 SETUP MAN GAIN ãÜÜÜÜÜÜÜÜÜ 10 0 Ø 3C 1 1 1 SETUP MAN GAIN ãÜÜÜÜÜÜÜÜÜ 10 0 Ø 3C 1 1 1 SETU...

Page 24: ...r of the available range as indicated on line 4 7 Press the ENTER key to store the change or press the MANUAL key to abort the change The system will exit the setup menus and return to the Operator Level Ø 3C 1 2 SETUP MAN GUIDE POINT ÜÜÜåÜÜÜ 0 0 Ø 3C 1 2 1 SETUP MAN GUIDE POINT ÜÜÜÜåÜÜÜÜ 0 0 Ø 3C 1 2 1 SETUP MAN GUIDE POINT ÜÜÜÜåÜÜ 20 0 Ø 3C 1 2 1 SETUP MAN GUIDE POINT ÜÜÜÜåÜÜÜÜ 0 0 3C MANUAL Ø ã...

Page 25: ... enter the BASIC Menus The GAIN menu will be displayed 3 Use the ARROW keys to scroll until CALIBRATION is displayed on line 3 4 Press the ENTER key to enter the CALIBRATION menu SELECT SENSOR will be displayed on line 3 If Center Guiding was the current sensor mode the sensor mode is forced to Edge Left X5 5 If necessary use the ARROW keys to select the desired sensor Edge Left or Edge Right to b...

Page 26: ...ress the MANUAL key to exit the setup menus and return to the Operator Level Repeat this procedure as necessary Ø 3B 1 4 2 UNCOVER SENSOR ÜÜÜÜÜÜÜÜÜÜ 0 WAIT 06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D 3X 1 4 Calibration Line Sensor Center of Line Guiding 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Press the ENTER key to e...

Page 27: ...e graphic at right The sensor signal is displayed on Line 3 Light Spot Line 9 Press the ENTER key If the contrast is sufficient for guiding SUCCESSFUL will be displayed for a few seconds on line 2 then the unit will automatically exit the menus and return to the Operator Level OR 10 If the contrast is not sufficient for guiding FAILED will be displayed on line 2 Press the MANUAL key to exit the se...

Page 28: ... ENTER key WAIT will be displayed for a few seconds on line 4 of the LCD Panel Maintain the web position during this wait period 8 Once the delay has ended COVER SENSOR will be displayed on line 2 Position the sensor such that the light spot is located fully on the line to be guided see graphic at right The sensor signal is displayed on Line 3 of the LCD Panel Light Spot Line 9 Press the ENTER key...

Page 29: ...SELECT SENSOR will be displayed on line 3 5 Use the ARROW keys to select the Servo Center Sensor ƒ will be displayed on line 1 and X2 will be displayed on line 4 6 Press the ENTER key to begin the calibration UNCOVER SENSOR will be displayed on line 2 Position the flag such that it is located away from the surface of the sensor see graphic at right The sensor signal is displayed on Line 3 of the L...

Page 30: ...screen numbers will correspond to the sensor mode that is selected 1 Position the the edge of the web or the center or edge of the line in the center of the sensor field of view See the appropriate graphic at right The ARROW keys may be used Edge Guiding Line Center Center Guiding Line Edge 2 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 3 P...

Page 31: ...the MANUAL key to exit the setup menus and return to the Operator Level The Guide Point and Deadband are restored to the values stored before the Auto Setup was attempted Repeat this procedure as required Ø 3B 1 5 3 POSITION WEB IN CENTER OF SENSOR ãããããÜÜÜÜÜ Ø 3B 1 5 4 SETUP MAN SUCCESSFUL 3B MANUAL Ø ãããããáÜÜÜÜ Ø 3B 1 5 3 SETUP MAN FAILED 3X 1 6 Servo Center Gain 1 Press the SETUP key to enter t...

Page 32: ...Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed 2 Press the ENTER key to enter the BASIC Menus The GAIN menu will be displayed 3 Use the ARROW keys to scroll until ƒ POLARITY is displayed on line 3 4 Press the ENTER key to allow adjustment of the Servo Center Polarity The current Polarity setting will begin flashing on line 4 5 Use the ARROW keys to adjust the...

Page 33: ...been scaled by values which were determined during the Sensor Calibration procedure 6 Use the ARROW keys to scroll to the desired Measurement menu Next in the list is the Servo Center Sensor The sensor signal is displayed on Line 4 7 Use the ARROW keys to scroll to the desired Measurement menu Next in the list is the TACHOMETER The tachometer signal is displayed on Line 4 8 Use the ARROW keys to s...

Page 34: ...his screen is displayed will exit the Measurement Menus and return to the Operator Level 13 Otherwise press the MANUAL key to exit the Measurement Menus and return to the Operator Level Ø 3C 1 8 6 MEASUREMENT DIGITAL INPUTS 000000 Ø 3C 1 8 7 MEASUREMENT FIRMWARE VERSION DP 20 Ver 1 00 Ø 3C 1 8 8 MEASUREMENT SERIAL NUMBER SN 01000 Ø 3C 1 8 9 MEASUREMENT EXIT MENUS 3C MANUAL Ø ãããããáÜÜÜÜ Special Men...

Page 35: ...MAN DEADBAND ÜÜÜÜÜÜÜ 0 0 3A 2 1 1 SETUP MAN DEADBAND ÜÜÜÜÜÜÜ 0 0 3A 2 1 1 SETUP MAN DEADBAND ÜÜÜãÜÜÜ 10 0 3A MANUAL ãããããáÜÜÜÜ 3X 2 2 Set Operation Mode Enable 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until SPECIAL is displayed on line 4 3 Press the ENTER key to enter the Special Menus The DEADBAND menu ...

Page 36: ... the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until SPECIAL is displayed on line 4 3 Press the ENTER key to enter the Special Menus The DEADBAND menu will be displayed 4 Use the ARROW keys to scroll until SENSOR ENABLE is displayed on line 3 The current selection is displayed on Line 4 5 Press the ENTER key to enter...

Page 37: ... Ø Ø YES NO NO 3A 2 3 4 SETUP MAN Ø Ø NO YES NO 3A 2 3 5 SETUP MAN Ø Ø YES NO YES 3A 2 3 6 SETUP MAN Ø Ø NO NO YES 3A 2 3 7 SETUP MAN Ø Ø NO YES YES 3A MANUAL ãããããáÜÜÜÜ 3X 2 3 Set Sensor Mode Enable Line Sensor 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until SPECIAL is displayed on line 4 3 Press the ENT...

Page 38: ...TUP MAN ý Ł YES YES ý 3D 2 3 2 SETUP MAN ý Ł YES NO 3D ý 3D 2 3 3 SETUP MAN ý Ł NO YES MANUAL ý ãããããáÜÜÜÜ 3X 2 4 Set Jog Enable 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until SPECIAL is displayed on line 4 3 Press the ENTER key to enter the Special Menus The DEADBAND menu will be displayed 4 Use the ARR...

Page 39: ... MAN NO YES NO NO YES YES 3A 2 4 4 SETUP MAN AUTO SC MAN 3A 2 4 5 SETUP MAN AUTO SC MAN YES NO NO 3A 2 4 6 SETUP MAN AUTO SC MAN YES NO YES 3A 2 4 7 SETUP MAN AUTO SC MAN YES YES NO 3A 2 4 8 SETUP MAN AUTO SC MAN YES YES YES 3A MANUAL ãããããáÜÜÜÜ 3X 2 5 Set Jog Polarity 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to s...

Page 40: ... 6 Set Jog Speed 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until SPECIAL is displayed on line 4 3 Press the ENTER key to enter the Special Menus The DEADBAND menu will be displayed 4 Use the ARROW keys to scroll until SET JOG SPEED is displayed on line 3 5 Press the ENTER key to enter the SET JOG SPEED me...

Page 41: ...ayed on line 3 The current sensor type is displayed on Line 4 5 Press the ENTER key to enter the SET SENSOR TYPE menu The current sensor type begins flashing on line 4 6 Use the ARROW keys to scroll to the desired sensor type EDGE SENSOR or LINE SENSOR as indicated on line 4 7 Press the ENTER key to store the change or press the MANUAL key to abort the procedure The system will exit the setup menu...

Page 42: ...ess the MANUAL key to abort the procedure The system will exit the setup menus and return to the Operator Level 3A 1 SETUP MAN SELECT MENU BASIC 3A 3 SETUP MAN SELECT MENU ADVANCED 3A 3 1 SETUP MAN RESTORE SETTINGS 3A 3 1 1 SETUP MAN RESTORE SETTINGS SURE YES 06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D 3X 3 2 Backup Settings This procedure stores all user configurable settings excep...

Page 43: ...S SURE YES 3A MANUAL ãããããáÜÜÜÜ 3X 3 3 Set Password Enter Password Use these menu instructions if no password is currently stored 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until ADVANCED is displayed on line 4 3 Press the ENTER key to enter the Advanced Menus The RESTORE SETTINGS menu will be displayed 4 ...

Page 44: ...A 3 3 3 SETUP MAN REENTER PASSWORD 3A 3 3 4 SETUP MAN PASSWORD STORED 3A MANUAL ãããããáÜÜÜÜ 3X 3 3 Set Password Delete Password Use these menu instructions only if a password is currently stored 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until ADVANCED is displayed on line 4 3 Press the ENTER key to enter t...

Page 45: ...ããáÜÜÜÜ 3X 3 3 Set Password Change Password Use these menu instructions only if a password is currently stored 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until ADVANCED is displayed on line 4 3 Press the ENTER key to enter the Advanced Menus The RESTORE SETTINGS menu will be displayed 4 Use the ARROW keys ...

Page 46: ...e the same as previously entered If a different password is entered WRONG PASSWORD will be displayed 12 Press the ENTER key to store the new password or press the MANUAL key to abort the procedure The system will exit the setup menus and return to the Operator Level X3A 3 3 SETUP MAN ENTER PASSWORD X3A 3 3 1 SETUP MAN SET PASSWORD CHANGE DISABLE X3A 3 3 2 SETUP MAN ENTER PASSWORD X3A 3 3 2 SETUP M...

Page 47: ...l exit the setup menus and return to the Operator Level 3A 3 1 SETUP MAN RESTORE SETTINGS 3A 3 4 SETUP MAN SET OUTPUT DELAY OUTPUT A 0 00s 3A 3 4 1 SETUP MAN SET OUTPUT DELAY OUTPUT A 0 00s 06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D 3X 3 5 Set Output B Delay 1 Press the SETUP key to enter the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys...

Page 48: ... the Setup Menus The SELECT MENU screen will be displayed on the LCD Panel 2 Use the ARROW keys to scroll until ADVANCED is displayed on line 4 3 Press the ENTER key to enter the Advanced Menus The RESTORE SETTINGS menu will be displayed 4 Use the ARROW keys to scroll until SET LOSS OF NULL is displayed on line 3 The current Loss Of Null value is displayed on line 4 5 Press the ENTER key to enter ...

Page 49: ... enter the DIGITAL I O menu The current setting will begin flashing 6 Use the ARROW keys to scroll to the desired setting ENABLED or DISABLED 7 Press the ENTER key to store the change or press the MANUAL key to abort the change The system will exit the setup menus and return to the Operator Level 3A 1 SETUP MAN SELECT MENU BASIC 3A 3 SETUP MAN SELECT MENU ADVANCED 3A 3 1 SETUP MAN RESTORE SETTINGS...

Page 50: ...ary use the ARROW keys to toggle to the desired sensor as indicated on line 3 The value of the sensor signal is shown on line 4 8 Press the MANUAL key to exit the setup menus and return to the Operator Level No settings are stored 3A 3 SETUP MAN SELECT MENU ADVANCED 3A 3 1 SETUP MAN RESTORE SETTINGS 3A 3 8 SETUP MAN TEST SIGNALS 3A 3 8 1 SETUP MAN SENSOR CURRENT 3A 3 8 1 1 SENSOR CURRENT SENSOR X5...

Page 51: ...xit the setup menus and return to the Operator Level No settings are stored and control of the outputs is returned to normal 3A 3 1 SETUP MAN RESTORE SETTINGS TEST SIGNALS 3A 3 8 2 SETUP MAN 3A 3 8 1 SETUP MAN SENSOR CURRENT TOGGLE OUTPUTS 3A 3 8 2 1 SETUP MAN OUT A OUT B OFF OFF 3A 3 8 SETUP MAN 3A 3 8 2 1 SETUP MAN OUT A OUT B ON ON 3A MANUAL ãããããáÜÜÜÜ 3X 3 8 3 Test Signals Guide Test Mode THIS...

Page 52: ...f the currently selected sensor simulating instantaneous 80 Guide Point Shifts If mode 2 is selected the guide oscillates back and forth within 80 of the bandwidth of the currently selected sensor simulating 4 steps in Guide Point Shift If mode 3 is selected the guide oscillates switching back and forth between the Guide Point of the left edge sensor and the Guide Point of the right edge sensor wi...

Page 53: ...n line 2 The unit will remain paused until another command is issued 11 Pressing the AUTOMATIC key will resume the oscillator action at the point it was paused OR 12 Pressing the MANUAL key a second time will exit the oscillator mode and return to the Operator Level 3A 3 8 3 1 RUNNING MODE1 1 ÜÜÜÜÜÜÜÜ 0 50s 3A 3 8 3 1 RUNNING MODE1 10 ÜÜÜÜÜÜÜÜ 0 01s 3A 3 8 3 1 PAUSED MODE1 10 ÜÜÜÜÜÜÜÜ 0 50s 3A 3 8...

Page 54: ...2 Use the ARROW keys to scroll until CUSTOM is displayed 3B MANUELL Ø ãããããáÜÜÜÜ 3A 1 SETUP MAN SELECT MENU BASIC 3 Press the ENTER key to enter the Custom Menus The ASC CONTROL menu will be displayed The current setting is displayed on line 4 4 If necessary press the SENSOR key to select the desired sensor mode 5 Press the ENTER key to enter the ASC CONTROL menu The contents of line 4 will begin ...

Page 55: ...red Press both ARROW keys simultaniously to reset the negative ASC value to the default 90 if desired 8 Press the ENTER key to switch to the positive ASC limit value or press the MANUAL key to abort the procedure If the MANUAL key is pressed any changes to the ASC Limit values will be discarded and the system will exit the setup menus and return to the Operator Level 9 If the ENTER key was pressed...

Page 56: ...Menus The ASC CONTROL menu will be displayed 4 Use the ARROW keys to scroll until SET ASC SOURCE is displayed on lin 3 The current setting is displayed on line 4 5 If necessary press the SENSOR key to select the desired sensor mode 6 Press the ENTER key to enter the SET ASC SOURCE menu The current setting will begin flashing 7 Use the ARROW keys to select the desired setting 8 Press the ENTER key ...

Page 57: ...4 5 are used to provide Jogs while in Manual and Servo Center modes and RGPC functions while in Automatic mode Sensor selection is allowed in Manual and Servo Center modes only Sensor selection must be momentary commands For sensor selection input 2 must be commanded either simultaneously with or prior to inputs 1 3 0 LOW 1 HIGH IGNORE Parallel Output Matrix OUTPUTS STATUS B A LOSS OF NULL AUTOMAT...

Page 58: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...

Page 59: ...an asterisk surrounded by parentheses is displayed on line 1 of the LCD Panel 11 When any Setup Menu is entered commands on the Parallel Port for Operation Mode and Sensor Mode are disabled to prevent interference with the setup process 12 If an SE 26A line sensor is to be used it must be connected to the X4 connector 13 The optional RGPC 40 Remote Guide Point Control connects to the X3 connector ...

Page 60: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...

Page 61: ...n Actuator moves the wrong direction in Automatic mode Guide Polarity is set incorrectly or Incorrect sensor mode selected Change Guide Polarity Select MANUAL mode then verify the correct sensor mode is selected If necessary press the SENSOR key to select the correct sensor mode 3X 1 3 Guide Polarity Actuator does not move in Servo Center mode Servo Center Gain is set too low Increase the Servo Ce...

Page 62: ...sts the unit must be repaired AC POWER FAIL fault 004 A failure of the AC Power was detected The unit will automatically reset If the fault persists the unit must be repaired EEPROM CRC fault 005 An error was detected in the EEPROM memory A configuration setting has changed unexpectedly causing this fault Press the ENTER key to exit the fault screen If it can be determined which configuration sett...

Page 63: ...ult persists the unit must be repaired EEPROM BUSY fault 011 This fault indicates that the EEPROM was busy when a memory write was attempted Press the ENTER key to exit the fault screen Repeat the last performed procedure If the fault persists the unit must be repaired 3A 0 007 FAULT EEPROM WRITE PRESS èéê XX 3A 0 008 FAULT WATCHDOG RESET PRESS èéê 3A 0 009 FAULT EXTERNAL DAC PRESS èéê 3A 0 010 FA...

Page 64: ... 9K 1 3 A 534734 001 Motor 16 9K GAB 1 GAG 2 PT 200 0 4A MOTOR 20 5K 0 4 A 66356 001 Motor 66356 002 Motor 20 5K NarroWeb 25 1 0A MOTOR 44 2K 1 0 A 65315 001 Actuator 65316 001 Actuator 44 2K NarroWeb 50 50mA HYDR 64 9K 50 mA Hydraulic Servo Valve 64 9K 48V LVALVE 78 7K 0 6 A Hydraulic Servo Valve and 48 V Lockout Valve 78 7K 24V LVALVE 95 3K 1 2 A Hydraulic Servo Valve and 24 V Lockout Valve 95 3...

Page 65: ...uts and Outputs Electromechanical Actuator Maximum 39 W at 30 V Hydraulic Servo Valve 50 mA With or without Lockout Valve Max 39 W at 24 V or 48 V MPA with MPA Lockout Signal 10 mA ServoCenter Analog Inductive type Sensor Input 2 Individually Max Input 20 mA Programmable 0 to 10 mA Preferred Parallel port Six Digital Inputs Low Level 0 0 9 V High level 3 6 24 V max 6 mA Two open collector outputs ...

Page 66: ...Sensor 25 m 82 ft Parallel Port 50 m 165 ft Servo Center 50 m 165 ft Servo Valve 50 m 165 ft Lockout Valve 50 m 165 ft Actuator 14 m 46 ft RGPC 40 100 m 330 ft FIFE CORPORATION 222 W Memorial Road Oklahoma City OK 73114 2317 USA Post Office Box 26508 Oklahoma City OK 73126 0508 USA Phone 405 755 1600 800 639 3433 Fax 405 755 8425 E mail fife fife com Web www fife com 06 05 2007 DP 20 WEB GUIDE CON...