20
EN
Drive unit unlocking / locking
- For safety reasons, carry out these operations after the power supply has
been disconnected because even in the case of power failure, the power supply
could be restored at any moment.
- Always lock the drive before connecting the power supply. The lever must be
in the locked position.
- Never unlock or lock the drive unit when the gate is running (displacement in
electric or manual mode).
When the drive is set in the unlocked position , the gate can be controlled manually in case of power failure.
Then the gate can be moved completely freely. Exercise caution when carrying out this operation.
Unlock the drive
unit by pulling
the lever towards
yourself.
Lock the drive
unit by pushing
the lever in the
direction of the
gate.
Operation of remote controls or transmitters with 3 push-buttons
Opening
by pressing the „Up”
push-button
Closing by pressing the
„Down” push-button
Stopping
by pressing the
central push-button
Note:
The remote controls or transmitters with 3 push-buttons do not allow opening the gate
in pedestrian entry mode.