Zone lighting -----------------------------------------------------
►
Conductors of orange light
Connect the orange light to the terminals 7 and 8 (orange label
„FLASH”) of the electronic module.
Emergency battery-------------------------------------------
This element is not compatible with a solar energy supply.
The emergency battery ensures the continuity of gate operation at low speed in case of electrical supply failure.
The battery is built in to the electronic module of the drive and connected with it directly.
To lengthen the amount of time of the battery operation, the wire control systems are disconnected; the gate is
controlled with remote controls and radio transmitters only.
Note: STATUS indicator
flashes (1 pulse) when the drive is supplied by the battery.
►
Technical data of the battery
•
Operating time: 10 cycles in continuous mode or 24 hours if the gate is in good technical condition.
• Optimum charging time for the battery before use: 48 hours.
• Battery life: 3 years.
To ensure optimum battery life, disconnect the power supply from the gate three times a year and run several
cycles with battery operated drive.
Connect the zone lighting to terminals 13 and 14 (white label
„LIGHT”) of the electronic module.
This element is not compatible with a solar
energy supply.
It is necessary to separate batteries and rechargeable batteries from other types of waste and to
transport them to a local waste collection area to be recycled.