14
EN
3. ELECTRICAL CONNECTIONS
Successive stages
• Connection of the drive unit
• Connection to power supply
• Connection to a solar energy source
• Connection of safety accessories
►
Connection of the drive
Always connect the drive unit and the electronic module before the
electronic module is connected to the mains.
Always connect the drive unit to the terminals 9 and 10 (green label M1
of the electronic module of the drive).
The drive unit (4) and the electronic module (3) are initially equipped with conductors designed for the drive
unit mounted on the left hand side. To change direction of the drive unit operation, interchange the conductors
connected to terminals 9 and 10.
Blue/Black
Brown/Green
9 10
M1
Blue/Black
Brown/Green
9 10
M1
The drive on the left-hand side
View from inside
The drive on the right-hand side
View from inside