8
EN
Preliminary wiring system
Provide the shield Orange ICT Ø 25 mm for cables located underground.
If cables cannot be laid underground, use a cable bush that can withstand being run over
by vehicles.
►
Mains supply (only with voltage 230 V)
Lead power supply of 230 V as close to the drive unit as possible.
The electronic module of the drive must be powered with voltage 230 V – 50 Hz using a flexible conductor
of 1,5 mm².
The electrical supply line must be:
• Designed for the drive only.
• Protected:
– by means of a fuse or a circuit breaker 10 A,
– by means of a differential gear (30 mA).
• Installed in accordance with the safety standards concerning wiring systems and effective in the country
of use.
Multipolar disconnection of power supply is to be provided:
• using a supply conductor with a plug,
• or by means of a switch where the distance between contacts is at least 3 mm for each pole (according
to EN 60335-1).
It is recommended to install a lightning rod (maximum residual voltage 2 kV).
►
Photocells (an option in Simple Move 101 set)
Photocells are necessary for operation in automatic mode and to open a gate.
• Photocell conductors (see page 23).
Provide a connection for the photocell conductors in the shield between the two gate posts. Drill holes
for shields in both ends of the gate construction. The photocells must be connected with the electronic
system of the gate using a cable 2x0.75
mm². Supply conductors must be led under the photocells.
• Location of the photocells (see page 23).
►
Orange light (option)
Installation of orange light is recommended for operation in automatic mode when opening the gate.
• Orange light conductors (see page 27).
Provide space for the conductor of the orange light. The orange light must be connected to the
electronic system of the drive using a conductor 2x0.75 mm².
•
Location of the orange light (see page 26).
Safety rules
Observe the following safety rules during installation:
• Remove any jewellery before commencing installation (bracelets, chains or any other items).
• Wear special safety goggles and proper protection during drilling or welding.
•
Use the appropriate tools as specified on page 6.
• Exercise caution during operation of the drive system to avoid the risk of injury..
• Do not connect the system to the mains or emergency battery (accessory equipment) before installation
is completed.
• Do not use high pressure water to clean the system.