16
EN
Successive stages
• Introduction to the remote control
• Placing the label on the electronic module
• Power up the system
• Gate track teaching
►
Introduction to the remote controls
The remote controls delivered in the set have been already programmed.
Push-button 1 of the remote control allows the complete opening
of the gate.
►
Placing the label on the electronic module
Stick the label (14) on the electronic module (3) of the drive unit.
►
Power up the system
Power up the system.
The STATUS indicator
on the electronic module flashes (2 pulses) to inform that the power supply of the
drives is ON and they are waiting for adjustment.
If the STATUS indicator remains unlit, see page 31.
►
Gate track teaching
The electronic system of the drive stores automatically the following:
• The necessary drive torque to control the gate in the usual mode. The saving of this information
allows detection of any abnormalities in the drive unit operation.
• The gate tracks during the opening and closing of the gate completely as well as the positions of the stops.
During setting the parameters, stand at the usual distance from the gate and carry out the following operations:
4. QUICK START-UP
Press push-button 1 of the remote control to
open / close the gate COMPLETELY.
The STATUS indicator
of the electronic
module should EMIT LIGHT CONTINUOUSLY.
If the STATUS indicator
flashes, see troubleshooting on
page 31.
Do not interrupt the gate movement (complete opening /
closing).
If the gate movement is interrupted, teaching will be
resumed automatically at the next opening.
1
2
Push-button 1
Push-button 2