0000100519/121212/0 MDB-2X/2F/4F
EN - 17
0
6
trOuBlEshOOtiNg
If the
MDB-2F/MDB-4F
does not function (correctly), consult
the checklist below to see if you can remedy the error
yourself. Should this not be possible, contact your supplier.
A number of problems in the checklist below can also be
caused by defects in the connected equipment. This manual
only deals with problems and solutions directly related to the
product itself
.
MDB-2F
symptom
Problem
Possible cause
solution
“Mains On” pilot light
does not light up
System does not
function
Main Switch off
Turn on main switch
No power supply
Check power supply
Fuse(s) defective
Check fuses F1 and F2 and replace if necessary
Fan does not start
running
System does not
function
Overload relay tripped
Check current settings and reset overload relay
Fuse defective
Check fuse F3 and replace if necessary
Motor defective
Replace motor
Controller defective
Replace controller
Buzzer sounds
Error in system
Error frequency converter
Check frequency converter error code
No air pressure
Check air pressure
Filter clogged
Replace filter
MDB-4F
symptom
Problem
Possible cause
solution
“Mains On” pilot light
does not light up
System does not
function
Main Switch off
Turn on main switch
No power supply
Check power supply
Fuse(s) defective
Check fuses F4 and F4 and replace if necessary
Fan does not start
running
System does not
function
Overload relay tripped
Check fuses F1, F2 and F3 and replace if necessary
Fuse defective
Check fuse F3 and replace if necessary
Frequency converter defective Replace frequency converter
Motor defective
Replace motor
Controller defective
Replace controller
Buzzer sounds
Error in system
Error frequency converter
Check frequency converter error code
No air pressure
Check air pressure
Filter clogged
Replace filter
Summary of Contents for MultiDust BANK 2F
Page 40: ...0000100519 121212 0 MDB 2F 2X 4F 390...
Page 41: ...0000100519 121212 0 MDB 2F 2X 4F 400...
Page 42: ...0000100519 121212 0 MDB 2F 2X 4F 410...
Page 43: ...0000100519 121212 0 MDB 2F 2X 4F 420...
Page 44: ...0000100519 121212 0 MDB 2F 2X 4F 430...
Page 45: ...0000100519 121212 0 MDB 2F 2X 4F 440...
Page 46: ...0000100519 121212 0 MDB 2F 2X 4F 450...