0000100519/121212/0 MDB-2X/2F/4F
EN - 4
0
Data sheet and general instructions
MDB-4-w3
MDB-4-w2
Explanation of the type
designation
Number of filter cartridges
2-4
Connection voltage
V
400
Frequency
Hz
50
Type of current
Ph
3
Power
kW
2,2
Norm. volumetric air flow
m
3
/h
1600
3750
1600
3750
Pressure
Pa
1600
550
1600
550
Filter area
m²
40
50
Filter insert
4 x times 10 m² filter
cartridges Cart-PTFE
Ref. 6840-1011
4 x times 15 m² filter
cartridges Cart D with min. 40
gram precoat per filter
cartridge Ref. 6815-1011
Max. volumetric air flow
Min. volumetric air flow
m³/h per filter cartridge
1000
350
1500
525
Fan
See the fan table
Control panel level of
protection
IP 55
Duty cycle
%
100
Dimensions
mm
See illustration
Weight
Kg
425
Welding fumes extraction
class and separation
performance
W3
> 99%
W2
> 98%
Use for the intended
purpose
Extraction of fumes that are
released in the course of using
welding equipment for cutting
and joining non-alloy and
alloy steels, including high-
alloy chromium/nickel steels
with a nickel and chromium
content of ≥ 30%
Extraction of fumes that are
released in the course of using
welding equipment for cutting
and joining non-alloy and alloy
steels, including high-alloy
chromium/nickel steels with a
nickel and chromium content of
≤ 30%
Excluded uses
-
Welding fumes containing oil
-
Aluminium dust
-
Burning or incandescent materials
-
Cigarettes
-
Aggressive media
-
Water and moisture
-
Explosive gases and/or dust mixtures
-
Dusts with toxic characteristics other than welding fumes
Type of cleaning
Pulse jet
Compressed air
Pressure and quality
Minimum 4 bar and maximum 6 bar
Dry and oil-free
Consumption
50 Ndm³ free air per pulse
Control system and warning
signals
Monitoring of air volumes and
lifetime of the filter cartridges
-
A pressure switch monitors the pressure drop across the filter
cartridges and activates a visual warning signal.
-
A flashing lamp is to be fitted. This performs 65 +/- 10
flashes per minute at 700-1000 cd in accordance with ISO-EN
842+A1.
-
Warning signal activation at loss of pressure 1500 Pa in the
course of 1 hour or longer acts as a request to exchange the
filter cartridge.
• Install the flashing lamp where it can easily be seen and
connect it in parallel with an alarm lamp on the control
panel SCP, Cont.B or Cont.C.
Direction of rotation of the
drive
Display indicating direction of rotation on the motor
If the direction of rotation is incorrect, swap over two phases in
the motor connection box.
Noise emission
dB(A)
See the fan table
Permissible ambient
conditions
°C (°F)
Min.
5 (41°F)
Norm.
20 (68°F)
Max.
45 (104°F)
Atmospheric humidity
75%
Storage conditions
Temperature in storage 5-45°C (41-104°F)
Atmospheric humidity in storage 75%
Summary of Contents for MultiDust BANK 2F
Page 40: ...0000100519 121212 0 MDB 2F 2X 4F 390...
Page 41: ...0000100519 121212 0 MDB 2F 2X 4F 400...
Page 42: ...0000100519 121212 0 MDB 2F 2X 4F 410...
Page 43: ...0000100519 121212 0 MDB 2F 2X 4F 420...
Page 44: ...0000100519 121212 0 MDB 2F 2X 4F 430...
Page 45: ...0000100519 121212 0 MDB 2F 2X 4F 440...
Page 46: ...0000100519 121212 0 MDB 2F 2X 4F 450...
Page 47: ...0000100519 121212 0 MDB 2F 2X 4F 460...
Page 48: ...0000100519 121212 0 MDB 2F 2X 4F 470...
Page 49: ...0000100519 121212 0 MDB 2F 2X 4F 480...
Page 50: ...0000100519 121212 0 MDB 2F 2X 4F 490...
Page 51: ...0000100519 121212 0 MDB 2F 2X 4F 500...
Page 52: ...www plymovent com 0000100519 121212 0 MDB 2X 2F 4F...