background image

0000100519/121212/0 MDB-2X/2F/4F

EN - 3

0

PrEFAcE

using this manual

This manual is intended to be used as a work of reference for 

professional, well-trained and authorized users to be able to 

safely install, use, maintain and repair the product 

mentioned on the cover of this document.

Pictograms and symbols

The following pictograms and symbols are used in this 

manual:

tiP

Suggestions and recommendations to simplify 

carrying out tasks and actions.

AttENtiON

A remark with additional information for the user. 

A remark brings possible problems to the user’s 

attention.

cAutiON!

Procedures, if not carried out with the necessary 

caution, could damage the product, the workshop 

or the environment.

wArNiNg!

Procedures which, if not carried out with the 

necessary caution, may damage the product or 

cause serious personal injury.

wArNiNg!

Denotes risk of electric shock.

wArNiNg!

Fire hazard! Important warning to prevent fire.

Use protection gloves, if not carried out with the 

necessary caution, may cause serious personal 

injury.
Use breathing protection, if not carried out with 

the necessary caution, may cause serious personal 

injury.

service and technical support

For information about specific adjustments, maintenance or 

repair jobs which are not dealt with in this manual, please 

contact the supplier of the product. He will always be willing 

to help you. Make sure you have the following specifications 

at hand:

- product name

- serial number

These data can be found on the identification plate. 

text indicators

Listings indicated by “-” (hyphen) concern enumerations.

Listings indicated by “•” (bullet point) describe steps to 

perform.

iNtrODuctiON

1.1 

Identification of the product

The identification plate contains, among other things, the 

following data:

 

-

product name 

 

-

serial number 

 

-

supply voltage and frequency 

 

-

power consumption

1.2 

general description

The

 MDB-2X

 is a self cleaning filter unit with integrated 

controls, including on/off fan control with overload protection 

up to 2.2 kW. The fan itself is not included. 

The 

MDB-2F

 is a self cleaning filter unit with integrated 

extraction fan of 1.1 kW and controls. 

The 

MDB-4F

 is a self cleaning filter unit with integrated 

extraction fan of 2.2 kW and controls. This product features 

a frequency inverter.

All the units are preassembled for easy installation. 

The fan pulls the air with particulate through the filters. 

When the pressure over the filter reaches a certain point, the 

internal self-cleaning mechanism begins to clean the filter 

cartridges by means of compressed air shots, resulting in the 

particulate dropping into a dustbin at the bottom of the unit.

Summary of Contents for MultiDust BANK 2F

Page 1: ...www plymovent com EN Central filter system DE Zentrale Filteranlage EN User manual DE Betriebsanleitung MultiDust BANK 2X 2F 4F...

Page 2: ...you This publication has been written with great care However the manufacturer cannot be held responsible either for any errors occurring in this publication or for their consequences de bersetzung d...

Page 3: ...0000100519 121212 0 MDB 2X 2F 4F 2 English Page MDB 2X 2F 4F 3 Electrical diagrams 39 DEUTSCH Seite MDB 2X 2F 4F 22 Schaltplane 39 TABLE OF CONTENTS...

Page 4: ...intenance or repair jobs which are not dealt with in this manual please contact the supplier of the product He will always be willing to help you Make sure you have the following specifications at han...

Page 5: ...chromium content of 30 Excluded uses Welding fumes containing oil Aluminium dust Burning or incandescent materials Cigarettes Aggressive media Water and moisture Explosive gases and or dust mixtures...

Page 6: ...nded and the MultiDust Bank repaired Dismantling and disposal Only a qualified electrician may disconnect the machine or the electrical system Before dismantling it the machine must be disconnected fr...

Page 7: ...cessories Specific working conditions or used accessories may require additional safety instructions Immediately contact your supplier if you detect a potential danger when using the product User manu...

Page 8: ...e use for which the technical product is suited as specified by the manufacturer inclusive of his directions in the sales brochure In case of doubt it is the use which can be deduced from the construc...

Page 9: ...electrical components Set the transformer on the primary voltage connection to the correct voltage position Fig 1 and 2 C Motor wiring The motor wiring has to be reconfigured according to the correspo...

Page 10: ...lt in serious personal injury or death warning Do not attempt installation of this unit unless you are familiar with the necessary tools equipment utility connections and potential hazards Installatio...

Page 11: ...sure that the front of the cartridge aligns with the filter housing so that the lid closes well If this is not the case it means that the filter cartridge has not been positioned correctly This may c...

Page 12: ...rt Alarm If the pressure drop stays above 1400 Pa for more than one hour an alarm will sound as indication to replace the filters MDB 4F Filter cleaning while the fan is running online cleaning If the...

Page 13: ...elayed off B Optional remote start stop ventilator with delayed off C Adjustable ventilator speed with potentiometer on the frequency converter or in case of 600V with potentiometer connected to frequ...

Page 14: ...ter The indicator moves to the next parameter in the display Use to browse to parameter Set up 2 and press OK to select this parameter To exit and confirm the new setting press Menu Control and set th...

Page 15: ...lock X1 in the control panel and the Pressure Transmitter The pressure transmitter should be mounted with the pressure connectors downwards The duct connector for the under pressure measurement should...

Page 16: ...a manual controlled frequency converter with a potentiometer adjust the airflow to the correct airflow for the application by using the potentiometer Check airflow regularly and adjust potentiometer i...

Page 17: ...protection class P3 The dust and the dirty filter cartridges must be properly disposed of in accordance with statutory instructions using the plastic sack disposal system supplied 5 1 Replacing filter...

Page 18: ...se defective Check fuse F3 and replace if necessary Motor defective Replace motor Controller defective Replace controller Buzzer sounds Error in system Error frequency converter Check frequency conver...

Page 19: ...32 8 7 Control box 31 5 4 1 11 10 6 2 13 14 15 12 26 25 27 22 24 23 18 19 17 3 33 0000100519 121212 0 MDB 2X 2F 4F EN 180 7 Spare parts Spare part drawing MDB 2F Front control box Back control box...

Page 20: ...Control box 9 8 7 3 32 5 4 1 29 26 25 27 30 12 17 18 19 20 21 16 15 22 24 23 28 31 11 10 6 2 33 0000100519 121212 0 MDB 2X 2F 4F EN 190 Spare part drawing MDB 4F...

Page 21: ...1 Main switch 29 935627 1 Frequency inverter 2 2kW 400V 30 935658 1 Frequency inverter 2 2kW control panel 29 935684 1 Frequency inverter 3kW 600V 31 994036 1 Compressed air switch 32 940571 1 Pressu...

Page 22: ...etherlands 12 December 2012 Ir F Coehoorn Vice President Research Development An installation is defined as a combination of several finished products or components that are assembled by an installer...

Page 23: ...turarbeiten die nicht in dieser Anleitung behandelt werden wenden Sie sich bitte an Ihren H ndler Er ist gern bereit Ihnen zu helfen Halten Sie in diesem Fall folgende Angaben bereit Produktname Serie...

Page 24: ...iener Die Bedienung des Produkts ist entsprechend geschulten und befugten Bedienern vorbehalten Vor bergehende Arbeitskr fte und Auszubildende d rfen das Produkt ausschlie lich unter Aufsicht und Vera...

Page 25: ...bereich betreten Bei Arbeiten auf H hen gr er als 2 Meter geeignete Kletterausr stung und Schutzvorrichtungen verwenden m glicherweise gelten rtliche Einschr nkungen Das Produkt nie vor Ein Aus oder D...

Page 26: ...von 240V 60Hz 3 ph verf gbar ist folgen Sie bitte den Schritten B bis D A Zugangsleitung Siehe Schaltplan 0517001110 B Transformatorverdrahtung Um Sch den an elektrischen Komponenten zu vermeiden mus...

Page 27: ...allation nur durch wenn Sie mit den entsprechenden Werkzeugen Apparaturen Betriebsanschl ssen und m glichen Gefahren vertraut sind Die Installation darf nur von einem qualifizierten Kundendienst vorge...

Page 28: ...rseite der Filterpatrone zum Filtergeh use ausgerichtet ist und der Deckel dadurch gut schlie t Ist dies nicht der Fall dann ist die Filterpatrone nicht korrekt positioniert Dies kann zu Leckstellen e...

Page 29: ...Reinigungszyklus 2 Impulse pro Ventil Alarm Wenn der Druckverlust mehr als eine Stunde ber 1400Pa betr gt ert nt ein Alarmsignal als Aufforderung die Filter auszutauschen MDB 4F Reinigung eingeschalt...

Page 30: ...B 4F Filteranlage 1 Ventilator manuell ein ausschalten mit verz gerter Ausschaltung 2 Ventilator ferngesteuert ein ausschalten mit verz gerter Abschaltung 3 Verstellbare Ventilatorgeschwindigkeit mit...

Page 31: ...Parameter befindet Bet tigen Sie die Pfeiltasten bis Sie zu Parameter 0 gelangen Mit OK best tigen Der Cursor bewegt sich zum n chsten im Display angezeigten Parameter Bet tigen Sie die Pfeiltasten bi...

Page 32: ...Bedienfeld befindliche Klemmenleiste X1 an Befestigen Sie den Druckgeber mit nach unten gerichteten Druckanschl ssen Der Rohranschluss f r die Unterdruckmessung erfolgt mit einem mindestens zweifache...

Page 33: ...r rect flow for the application Check airflow regularly and open damper more if necessary to correct airflow The airflow and damper position will become constant after the breaking in period this can...

Page 34: ...Einsetzen einer neuen Filterpatrone gegen die Wand des Filtergeh uses dr ckt HINWEIS Nach dem Wechseln der Filterpatronen m ssen die Startabl ufe befolgt werden N here Informationen in diesem Handbuc...

Page 35: ...ng defekt Sicherung F3 berpr fen und ggf ersetzen Motor defekt Motor ersetzen Defekte SPS Steuerung SPS Steuerung austauschen Summer ert nt Fehler im System St rung von Frequenzumrichter berpr fen Sie...

Page 36: ...32 8 7 Control box 31 5 4 1 11 10 6 2 13 14 15 12 26 25 27 22 24 23 18 19 17 3 33 0000100519 121212 0 MDB 2X 2F 4F DE 350 ERSATZTEILLISTE MDB 2F...

Page 37: ...Control box 9 8 7 3 32 5 4 1 29 26 25 27 30 12 17 18 19 20 21 16 15 22 24 23 28 31 11 10 6 2 33 0000100519 121212 0 MDB 2X 2F 4F DE 360 ERSATZTEILLISTE MDB 4F...

Page 38: ...1 Main switch 29 935627 1 Frequency inverter 2 2kW 400V 30 935658 1 Frequency inverter 2 2kW control panel 29 935684 1 Frequency inverter 3kW 600V 31 994036 1 Compressed air switch 32 940571 1 Pressu...

Page 39: ...inem bestimmten Ort zusammengebaut werden Die unterschiedlichen Komponenten der Anlage sind f r einen gemeinsamen Betrieb in einer bestimmten Betriebsumgebung bestimmt und haben eine spezifische Aufga...

Page 40: ...0000100519 121212 0 MDB 2F 2X 4F 390...

Page 41: ...0000100519 121212 0 MDB 2F 2X 4F 400...

Page 42: ...0000100519 121212 0 MDB 2F 2X 4F 410...

Page 43: ...0000100519 121212 0 MDB 2F 2X 4F 420...

Page 44: ...0000100519 121212 0 MDB 2F 2X 4F 430...

Page 45: ...0000100519 121212 0 MDB 2F 2X 4F 440...

Page 46: ...0000100519 121212 0 MDB 2F 2X 4F 450...

Page 47: ...0000100519 121212 0 MDB 2F 2X 4F 460...

Page 48: ...0000100519 121212 0 MDB 2F 2X 4F 470...

Page 49: ...0000100519 121212 0 MDB 2F 2X 4F 480...

Page 50: ...0000100519 121212 0 MDB 2F 2X 4F 490...

Page 51: ...0000100519 121212 0 MDB 2F 2X 4F 500...

Page 52: ...www plymovent com 0000100519 121212 0 MDB 2X 2F 4F...

Reviews: