0000100519/121212/0 MDB-2X/2F/4F
EN - 16
0
5
MAiNtENANcE
Replacing filter cartridges or emptying dustbins
• Shut off the compressed air feed and empty the pressure
tank(s) of air by opening the drain valve(s) on the back
of the filter.
NOTE: The power must always be switched off at the
circuit-breaker or by the line fuses. Protective gloves and
mask should always be used.
wArNiNg!
Always wear face mask and gloves during filter
exchange/cleaning.
wArNiNg!
Make sure the Cart-D filter cartridges are properly
installed. Improper installation will cause internal
leakage and a reduces filter efficiency. In combi
-
nation with SHIELD fire safety solutions it can lead
to a false fire alarm.
-
Maintenance work and functional testing should be
performed regularly to TRGS 560 section 5, paragraph 9
and to TRGS 528.
-
During maintenance the machine must be deenergised and
secured against switching on again.
-
Before erection, clean the equipment.
-
The maintenance area must be cleaned afterwards.
-
During maintenance work the working area must be
adequately ventilated; this can be achieved by provision of
a mobile ventilation unit.
-
During maintenance, appropriate personal protective
equipment should be worn. We recommend half-face
breathing masks to DIN EN 141/143, protection class P3.
-
The dust and the dirty filter cartridges must be properly
disposed of in accordance with statutory instructions, using
the plastic sack disposal system supplied.
5.1
Replacing filter cartridges
To change the filters with minimum release of dust into the
atmosphere, first change the upper filter cartridges and then
the lower ones.
Remove the filter cartridges from the MultiDust Bank
carefully, taking care not to jog them.
Wear the disposable gloves supplied with the replacement
filters, and place the used filter cartridges in the plastic sack
supplied.
• Unscrew the knob.
• Take off the cover lid and unscrew the nut, metal washer
and rubber ring that hold the filter cartridge.
• Take out the filter cartridge.
• Place the used filter cartridge in the packing of the
replacement filter and seal securely.
• Replace in reverse order. (The filter cartridge can only be
mounted in one way).
• Check that the cover lid presses against the filter housing
wall when a new filter cartridge has been fitted.
NOTE: when changing filter cartridges, the start-up routines
must be followed. See start-up procedure in this manual.
NOTE !
5.2
Emptying dustbins
The dustbin must be emptied regularly:
• Loosen the lock ring.
• Lower the dustbin by releasing the dustbin lift.
• Pull out the dustbin to remove the plastic bag.
• Seal the plastic bag before removing it from the dustbin.
• Fit a new plastic bag, place the dustbin, lift it up and put
locking ring back in place.
Summary of Contents for MultiDust BANK 2F
Page 40: ...0000100519 121212 0 MDB 2F 2X 4F 390...
Page 41: ...0000100519 121212 0 MDB 2F 2X 4F 400...
Page 42: ...0000100519 121212 0 MDB 2F 2X 4F 410...
Page 43: ...0000100519 121212 0 MDB 2F 2X 4F 420...
Page 44: ...0000100519 121212 0 MDB 2F 2X 4F 430...
Page 45: ...0000100519 121212 0 MDB 2F 2X 4F 440...
Page 46: ...0000100519 121212 0 MDB 2F 2X 4F 450...
Page 47: ...0000100519 121212 0 MDB 2F 2X 4F 460...
Page 48: ...0000100519 121212 0 MDB 2F 2X 4F 470...
Page 49: ...0000100519 121212 0 MDB 2F 2X 4F 480...
Page 50: ...0000100519 121212 0 MDB 2F 2X 4F 490...
Page 51: ...0000100519 121212 0 MDB 2F 2X 4F 500...
Page 52: ...www plymovent com 0000100519 121212 0 MDB 2X 2F 4F...